Automatic and Interactive Analysis Software for Beta- Gamma Coincidence Systems Used in Ctbt Monitoring
نویسنده
چکیده
A suite of software has been developed by Veridian Systems as part of the Prototype International Data Center (PIDC) to assist in the analysis of noble gas monitoring data for the Comprehensive Nuclear-TestBan Treaty (CTBT). There are two acceptable noble gas monitoring methods for CTBT verification purposes: high-resolution gamma-ray ( ) spectrometry and beta-gamma ( ) coincidence. Data from spectrometry systems can be analyzed with the existing software at the PIDC and the International Data Center (IDC). Because commercially available software did not exist to analyze data from the coincidence systems, this software has been developed at the PIDC for eventual deployment at the IDC. The suite of software consists of automatic analysis software and CORIANT (COincident Radiation Interactive ANalysis Tool). The automatic analysis software automatically identifies and quantifies radionuclides present in the sample and categorizes the sample based on the type and quantity of radionuclides present. CORIANT is a graphical user interface that gives an analyst the capability to view three-dimensional β-γ coincidence data, view automatic analysis results, view temporal trends in the data, generate reports, and override the automatic analysis if needed. A general description of the automatic analysis software and CORIANT, and the implementation of this software at the PIDC are discussed in this paper.
منابع مشابه
روشی جدید برای اندازهگیری پارامترهای چشمههای آلفازای فوق اورانیوم
An alpha-gamma coincidence method, using multi-parameter analyzer (MPA) system in list mode was used for measuring parameters of transuranium sources. The benefit of using the list method is preventing duplication of experiments a lot and thus saving the cost and time taken for this type of testing that due to very small sample rate, spend a lot of time. The multi-parameter analyzer stores the ...
متن کاملCharacterizing a Two-channel Phoswich Detector Using Radioxenon Isotopes Produced in the Oregon State University Triga Reactor
Low concentrations of radioxenon isotopes can be measured with a high sensitivity using beta/gamma coincidence technique. In this technique, a coincidence event is recorded when two signals from beta and gamma detection channels are detected simultaneously. These two coincident signals are then processed to establish a two-dimensional beta/gamma coincidence spectrum in which the four radioxenon...
متن کاملDesign and Modeling of a Compton-suppressed Phoswich Detector for Radioxenon Monitoring
By measuring the concentration of four xenon radioisotopes in the atmosphere, the International Monitoring System (IMS) can verify nuclear weapons tests around the world. To measure ultra-low concentrations of radioxenons, many detection systems, such as the Automated Radioxenon Sampler and Analyzer (ARSA) and the Swedish Automatic Unit for Noble gas Acquisition (SAUNA), have been developed and...
متن کاملNEW TYPES OF FUZZY n-ARY SUBHYPERGROUPS OF AN n-ARY HYPERGROUP
In this paper, the new notions of ``belongingness ($in_{gamma}$)"and ``quasi-coincidence ($q_delta$)" of a fuzzy point with a fuzzyset are introduced. By means of this new idea, the concept of$(alpha,beta)$-fuzzy $n$-ary subhypergroup of an $n$-aryhypergroup is given, where $alpha,betain{in_{gamma}, q_{delta},in_{gamma}wedge q_{delta}, ivq}$, andit is shown that, in 16 kinds of $(alpha,beta...
متن کاملDigital Pulse Shape Analysis with Phoswich Detectors to Simplify Coincidence Measurements of Radioactive Xenon
The Comprehensive Nuclear-Test-Ban Treaty establishes a network of monitoring stations to detect radioactive xenon in the atmosphere from nuclear weapons testing. One such monitoring system is the Automated Radioxenon Sampler/Analyzer (ARSA) developed at Pacific Northwest National Laboratory, which uses a complex arrangement of separate beta and gamma detectors to detect beta-gamma coincidences...