Alternative AOAC sporicidal test carrier for evaluating peracetic acid-based sterilants (modification of AOAC official method 966.04).
نویسنده
چکیده
Dacron suture loops were demonstrated to be inert, consistent carriers in the presence of peracetic acid-based sterilants, whereas black silk sutures had a variable preparation process and interacted with peracetic acid. In addition, Dacron suture loops provided comparable spore loading to black silk suture loops and an HCI resistance of > or = 2 min. These results indicate that black silk suture loops are not appropriate carriers for assessing peracetic acid-based sterilants, and Dacron loops are an acceptable alternative. This finding is consistent with the Office of Science and Technology Laboratory (Center for Devices and Radiological Health) study which determined that "polyester suture material is a viable alternative to silk for the AOAC sporicidal test for liquid disinfectants."
منابع مشابه
The differential effects of heat-shocking on the viability of spores from Bacillus anthracis, Bacillus subtilis, and Clostridium sporogenes after treatment with peracetic acid- and glutaraldehyde-based disinfectants
This study investigated (1) the susceptibility of Bacillus anthracis (Ames strain), Bacillus subtilis (ATCC 19659), and Clostridium sporogenes (ATCC 3584) spores to commercially available peracetic acid (PAA)- and glutaraldehyde (GA)-based disinfectants, (2) the effects that heat-shocking spores after treatment with these disinfectants has on spore recovery, and (3) the timing of heat-shocking ...
متن کاملA suspension method to determine reuse life of chemical disinfectants during clinical use.
In-use testing of disinfectants is necessary to ensure efficacy over time. The current official procedure for testing disinfectants, the Association of Official Analytical Chemists (AOAC) use-dilution method, cannot be adapted to repeated sampling techniques of use-life testing. It is therefore necessary to use an alternative method when evaluating the activity of a disinfectant under actual us...
متن کاملIn-house validation study for salmonella unique testing of juice (modification of AOAC official method 2000.07).
Following an industry request, a study was undertaken to validate a minor change to the Unique method for testing fruit juice. Twenty foods were tested in the original precollaborative study for TECRA Unique Salmonella test (2000.07). To validate the modification for juice, both the modified method (42 degrees C module incubation with a 5 h replication step) and the current AOAC Method 2000.07 ...
متن کاملEffect of methodology, dilution, and exposure time on the tuberculocidal activity of glutaraldehyde-based disinfectants.
The Association of Official Analytical Chemists (AOAC) test for assessing the tuberculocidal activity of disinfectants has been shown to be variable. A modified AOAC test, which substituted Middlebrook 7H9 broth as the primary subculture medium and used neutralization by dilution, was compared with the standard AOAC method to assess the mycobactericidal activity of three glutaraldehyde-based di...
متن کاملIsolation of light filth from ground oregano and ground marjoram: a modification using isopropanol as a defatting agent: in-house study.
A procedural modification of the AOAC Official Method for extracting light filth from ground oregano and ground marjoram was tested in an intralaboratory study. The modified method specifies isopropanol defatting, 975.49A(a), rather than chloroform-isopropanol defatting, 975.49A(b), followed by direct flotation as directed in AOAC Official Method, 975.49B(b). The modified method provided compar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of AOAC International
دوره 86 2 شماره
صفحات -
تاریخ انتشار 2003