A double mirror W/C multilayer monochromator for radiation biology applications.

نویسندگان

  • J F MacKay
  • D W Pearson
  • B E Nelms
  • P M DeLuca
  • M N Gould
  • M G Lagally
چکیده

A double-mirror multilayer monochromator was developed for the purpose of irradiating live cell cultures at the Synchrotron Radiation Center, University of Wisconsin-Madison. The monochromator is designed for the soft x-ray region with photon energies between 270 and 2400 eV. Multilayer mirrors with 55 bilayers of W/C and a bilayer spacing of d = 3.0 nm are sputter deposited on Si substrates. By proper masking of the sputtering sources, variation in the bilayer spacing over the area of the mirror is minimized. The uniformity of the bilayer spacing was measured to be delta d/d < 1%, over the 75 mm x 25 mm area of the mirrors. The reflectivity was measured as a function of energy to determine the integrated reflectivity and evaluate the contribution of the specular reflection and higher orders to the monochromatic beam. The use of suitable filters with a Si(Li) detector allows determination of the spectral output of the monochromator. The output power of the monochromator between 270 and 2400 eV is measured. The resolution of the monochromator is delta lambda/lambda = 0.04. Applications of the monochromator to radiation biology are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

X-ray imaging of microobjects using dark field refraction-contrast method with resonantly absorbing multilayer mirrors

An x-ray multilayer mirror, specially designed to produce resonant absorption at a definite angle of incidence, may be used as an angular dispersive element for refractive x-ray radiography. In this method the signal-to-noise ratio can be significantly enhanced due to suppression of the shot noise produced by the direct beam. Refraction contrast of a copper wire 75 μm in diameter and a human ha...

متن کامل

Performance of the Double Multilayer Monochromator

A tunable, double multilayer x-ray monochromator has recently been implemented on the National Synchrotron Light Source (NSLS) X25 wiggler beam line. It is based on a parallel pair of tungsten-boron-carbide multilayer films grown on silicon substrates and purchased from Osmic, Inc. of Troy, Michigan, USA. It acts as an optional alternative to the conventional double silicon crystal monochromato...

متن کامل

A high-throughput structural biology/proteomics beamline at the SRS on a new multipole wiggler.

The North West Structural Genomics Centre's beamline, MAD10, at the SRS receives the central part of the radiation fan (0.5 mrad vertically, 4 mrad horizontally) produced by a new 2.46 T ten-pole wiggler. The optical arrangement of the beamline consists of a Rh-coated collimating Si mirror, a fixed-exit-beam double-crystal monochromator with sagittal bending for horizontal focusing and a second...

متن کامل

Crystallographic data collection using a 0.22% bandwidth multilayer.

To bridge the gap between traditional multilayer and crystal optics a high-resolution multilayer monochromator with a bandwidth of 0.22% has been designed and installed on a bending-magnet beamline (F3) at the Cornell High Energy Synchrotron Source (CHESS) to provide an unfocused monochromatic X-ray beam for protein crystallography experiments. Crystallographic data of excellent quality from a ...

متن کامل

Reflection on multilayer mirrors: beam profile and coherence properties

The main advantage of Bragg reflection from a multilayer mirror as a monochromator for hard X-rays, is the higher photon flux density because of the larger spectral bandpass compared with crystal lattice reflection. The main disadvantage lies in the strong modulations of the reflected beam profile. This is a major issue for micro-imaging applications, where multilayer-based monochromators are f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 25 5  شماره 

صفحات  -

تاریخ انتشار 1998