A Comparison of Two Immunoassays for Analysing Plasma 25- hydroxyvitamin D
نویسندگان
چکیده
A total of 1628 human plasma samples from Cycle 1 of the Canadian Health Measures Survey were assayed for total 25-hydroxyvitamin D using the DiaSorin RIA method and the Diasorin “LIAISON 25 OH Vitamin D Total” method. Bland-Altman comparison showed an average bias of 4.8 ± 16.7 nmol/L (6.3%: P<0.001) with the LIAISON method giving higher values. The relationship was investigated using linear and Deming regression. Linear regression gave: LIAISON = RIA*(0.87 ± 0.02) + (13.3 ± 1.2) (mean ± SE) and weighted Deming regression (constant CV) gave: LIAISON = RIA*(1.14 ± 0.02) (4.2 ± 1.2). The significant deviations from a slope of unity and the significant non-zero intercepts were further investigated using non-linear regression. Quadratic regression gave: LIAISON = RIA 2 * (-0.0025 ± 0.0005) + RIA*(1.211 ± 0.07) + (2.9 ± 2.5). The intercept was not significantly different from 0. The quadratic equation significantly decreased the residual sum of squares (P<0.0001) indicating this model better described the relationship. Non-linearity was apparent at RIA 25-hydroxyvitamin D 110 nmol/L, where the relationship was described by: LIAISON = 97.5339 + 0.1388*RIA (r 2 = 0.0039; N.S.). However, removing points RIA 110 nmol/L did not substantially alter the regression parameters. Comparing the analytical imprecision with the total random regression error (Sy/x) suggested that sample-related effects were not present. It is recommended that cross-over analysis between these two methods include points from all parts of the range of interest to elucidate the complete nature of the relationship.
منابع مشابه
Performance evaluation of two immunoassays for 25-hydroxyvitamin D
Although immunoassays in measuring 25-hydroxyvitamin D [25(OH)D] have been improved recently, relatively large differences are still seen between results of 25(OH)D measured by immunoassays and by liquid chromatography-tandem mass spectrometry (LC-MS/MS). In the present studies, we compared two immunoassays with LC-MS/MS for measuring 25(OH)D concentrations. Concentrations of 25-hydroxyvitamin ...
متن کاملComparison of 25-hydroxyvitamin D and Calcium Levels between Preeclampsia and Normal Pregnant Women and Birth Outcomes
Introduction The main aim of this study was to compare serum level of 25- hydroxyl vitamin D [25(OH) D] between women with preeclampsia and normal individuals and birth outcomes. Material and Methods This cross sectional study was conducted on 650 normal primigravida women in their first 24–28 weeks of pregnancy. After 3 months of follow-up, serum levels of 25(OH) D and calcium were measured...
متن کاملComparison of 25-hydroxyvitamin D and Calcium Levels between Polycystic Ovarian Syndrome and Normal Women
Background Given the relationship of vitamin D deficiency with insulin resistance syndrome as the component of polycystic ovary syndrome (PCOS), the main aim of this study was to compare serum level of 25- hydroxyvitamin D [25(OH)D] between PCOS patients and normal individuals. MaterialsAndMethods A cross sectional study was conducted to compare 25(OH)D level between117 normal and 125 untreated...
متن کاملEvaluation of the cross-reactivity of 25-hydroxyvitamin D2 on seven commercial immunoassays on native samples.
Introduction: In serum, 25-hydroxy-vitamin D (25(OH)D) can be found in two forms, namely 25(OH)D2 and 25(OH)D3. We recently published a mathematical method to estimate the 25(OH)D2 recovery without spiking the samples. Since then, new “total” vitamin D immunoassays have appeared on the market (Roche “Total” vitamin D, Siemens Centaur vitamin D “total”, “total” vitamin D on DiaSorin Liaison XL, ...
متن کاملA comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry
INTRODUCTION Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatography-tandem mass spectrometry (LC-MS/MS). MATERIALS AND METHODS One hundred venous blood samples were randomly selected ...
متن کامل