Impact of QRS morphology and duration on outcomes after cardiac resynchronization therapy: Results from the Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT).
نویسندگان
چکیده
BACKGROUND The impact of QRS morphology and duration on the effectiveness of cardiac resynchronization therapy (CRT) has been usually assessed separately. The interaction between these 2 simple ECG parameters and their effect on CRT has not been systematically assessed in a large-scale clinical trial. METHODS AND RESULTS The Resynchronization-Defibrillation for Ambulatory Heart Failure Trial showed that implantable cardioverter defibrillator-CRT was associated with a significant reduction in the primary end point of all-cause mortality or heart failure hospitalization. For this substudy, we excluded patients in atrial fibrillation and those with a previous pacemaker. All baseline ECGs were reviewed by a panel of 3 experienced electrocardiographers. A total of 1483 patients were included in this study. Of these, 1175 had left bundle-branch block (LBBB) and 308 had non-LBBB. In patients with LBBB receiving implantable cardioverter defibrillator-CRT, there was a reduction in the primary outcome and in each individual component of the primary outcome. Furthermore, there was continuous relationship between QRS duration and extent of benefit. In patients with non-LBBB and QRS ≥160 ms, the hazard ratio for the primary outcome was 0.52 (0.29-0.96; P=0.033); in patients with QRS <160 ms, the hazard ratio was 1.38 (0.88-2.14; P=0.155). CONCLUSIONS In patients with LBBB, there was a continuous relationship between broader QRS and greater benefit from implantable cardioverter defibrillator-CRT. However, our data do not support the use of implantable cardioverter defibrillator-CRT in patients with non-LBBB, especially when the QRS duration is <160 ms. There may be some delayed benefit when the QRS is ≥160 ms, but this needs further investigation. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00251251.
منابع مشابه
Heart Failure Effect of QRS Duration and Morphology on Cardiac Resynchronization Therapy Outcomes in Mild Heart Failure Results From the Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction (REVERSE) Study
Background—Cardiac resynchronization therapy (CRT) decreases mortality, improves functional status, and induces reverse left ventricular remodeling in selected populations with heart failure. We aimed to assess the impact of baseline QRS duration and morphology and the change in QRS duration with pacing on CRT outcomes in mild heart failure. Methods and Results—Resynchronization Reverses Remode...
متن کاملEffect of QRS duration and morphology on cardiac resynchronization therapy outcomes in mild heart failure: results from the Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction (REVERSE) study.
BACKGROUND Cardiac resynchronization therapy (CRT) decreases mortality, improves functional status, and induces reverse left ventricular remodeling in selected populations with heart failure. We aimed to assess the impact of baseline QRS duration and morphology and the change in QRS duration with pacing on CRT outcomes in mild heart failure. METHODS AND RESULTS Resynchronization Reverses Remo...
متن کاملCardiac resynchronization therapy in patients with heart failure and a QRS complex <120 milliseconds: the Evaluation of Resynchronization Therapy for Heart Failure (LESSER-EARTH) trial.
BACKGROUND Although the benefits of cardiac resynchronization therapy are well established in selected patients with heart failure and a prolonged QRS duration, salutary effects in patients with narrow QRS complexes remain to be demonstrated. METHODS AND RESULTS The Evaluation of Resynchronization Therapy for Heart Failure (LESSER-EARTH) trial is a randomized, double-blind, 12-center study th...
متن کاملCardiac resynchronization therapy in patients with permanent atrial fibrillation: results from the Resynchronization for Ambulatory Heart Failure Trial (RAFT).
BACKGROUND Cardiac resynchronization (CRT) prolongs survival in patients with systolic heart failure and QRS prolongation. However, most trials excluded patients with permanent atrial fibrillation. METHODS AND RESULTS The Resynchronization for Ambulatory Heart Failure Trial (RAFT) randomized patients to an implantable cardioverter defibrillator (ICD) or ICD+CRT, stratified by the presence of ...
متن کاملImpact of Cardiac Resynchronization Therapy on Hospitalizations in the Resynchronization-Defibrillation for Ambulatory Heart Failure Trial Running title: Gillis et al.; Hospitalizations in RAFT
Dept of Cardiac Sciences, University of Calgary, Libin Cardiovascular Institute of Alberta, Calgary, Alberta; St Paul’s Hospital, Vancouver, British Columbia; Quebec Heart and Lung Institute, Sainte Foy, Quebec; Mount Sinai Hospital, Toronto, Ontario; Montreal Heart Institute and Université de Montreal, Montreal, Quebec; University of Ottawa Heart Institute, Ottawa, Ontario; University of Ottaw...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Heart failure
دوره 6 6 شماره
صفحات -
تاریخ انتشار 2013