Experimental study of track density distribution on LR 115 detector and deposition fraction of 218 Po in diffusion chamber
نویسندگان
چکیده
The radial distribution of track density on a solid-state nuclear track detector inside a diffusion chamber is a function of the fraction f of Po decay before deposition. In the present work, procedures are proposed to determine f experimentally by determining the track density distribution on an LR115 detector in a diffusion chamber. First, a relatively tall diffusion chamber, with a height of 8 cm, was chosen. After exposure, the LR115 detector was etched. A transparent template with concentric circles was devised to study the radial distribution of sensitivity using an optical microscope. The distributions according to different values of f were also calculated using Monte Carlo simulations. By minimizing the deviations between these Monte Carlo curves and the experimental data, f was found to be 0.4. r 2002 Elsevier Science B.V. All rights reserved.
منابع مشابه
Sensitivity of LR 115 SSNTD in a diffusion chamber
Solid-state nuclear track detectors (SSNTDs), such as LR 115, have been commonly used in diffusion chambers for long-term measurements of radon gas concentrations. For the LR 115 SSNTD, it has been found that the active layer removed during chemical etching is significantly affected by the presence and amount of stirring, and thus cannot be controlled easily. However, the sensitivity of the LR ...
متن کاملSensitivity of LR 115 detectors in hemispherical chambers for radon measurements
We have determined the detection sensitivity of the LR 115 detector placed on the bottom of hemispherical diffusion chambers through Monte Carlo simulations. For the cases where the LR 115 detectors completely cover the bottom of hemispherical diffusion chambers, we propose the optimum radius of the hemispherical chamber as 3 cm. In hemispherical chambers with radii smaller than 3 cm, the total...
متن کاملDerivation of V function for LR 115 SSNTD from its sensitivity to 220Rn in a diffusion chamber.
The sensitivity of the LR 115 detector inside a diffusion chamber to (220)Rn gas concentration is dependent on the removed active layer thickness during chemical etching. This dependence is related to the V function for the LR 115 detector (where V is the ratio between the track etch velocity V(t) and the bulk etch velocity V(b)) and the geometry of the diffusion chamber. The present paper pres...
متن کاملNuclear Track Detectors
Approximately half of the human exposure to radiation is due to indoor airborne shortlived progeny (decay products) of the radon gas (Rn). To measure the airborne concentrations of radon gas and/or its progeny, Nuclear Track Detectors (NTDs) are usually employed. The NTDs register the alpha particles emitted by radon gas and its progeny in the form of tracks in the NTDs, which will become visib...
متن کاملUse of LR-115 Detector to Measure Radon Concentrations in Milk and Tea Samples Collected From Misan Markets in Iraq
Introduction: Radioactive material is always present in the environment, and the largest contribution to the inhalation exposure comes from the short half-life decay products of radon. Accordingly, the concentrations of radon were measured in the milk and tea samples collected from Misanmarkets in Iraq. Material and Methods: A total of 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -