Measurement Accuracy of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Validation Report for Microlife WatchBP Office Central Hao-Min Cheng1,2,4,5, Shih-Hsien Sung3,4,6, Yuan-Ta Shih7, Shao-Yuan Chuang8, Wen-Chung Yu3,4,5, Chen-Huan Chen2,4,5,6

نویسندگان

  • Sung
  • Chuang
چکیده

METHodS The CBP monitor provided readings of brachial systolic BP (SBP), brachial diastolic BP (DBP), central SBP, and central pulse pressure (PP). Brachial PP and central DBP were calculated from the relevant readings. The accuracy of the brachial and central SBP, PP, and DBP was validated against the simultaneously recorded invasively measured central aortic SBP, PP, and DBP, according to the invasive standard requirements for the noninvasive brachial BP monitors from the Association for the Advancement of Medical Instrumentation (AAMI) in 85 subjects (255 measurements; age range, 30–93 years). rESuLTS The mean differences of cuff BP with reference to the invasively measured central SBP, PP, and DBP were −2.6 ± 9.0, −8.6 ± 11.2, and 6.1 ± 7.0 mm Hg, respectively, with the former two being obviously underestimated at high CBP and overestimated at low CBP. In contrast, the corresponding differences for the central SBP, PP, and DBP measured by the CBP monitor were −0.6 ± 5.5, −0.4 ± 7.0, and −0.2 ± 6.5 mm Hg, respectively, without obvious systematic bias. The distribution of measurement errors for central SBP, PP, and DBP surpassed the AAMI criteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of central aortic pulse pressure: noninvasive brachial cuff-based estimation by a transfer function vs. a novel pulse wave analysis method.

BACKGROUND The prognostic value of central aortic pulse pressure (PP-C) may have been underestimated due to its measurement inaccuracy. We aimed to investigate the accuracy of noninvasive brachial cuff-based estimation of PP-C by a generalized transfer function (GTF) or a novel pulse wave analysis (PWA) approach to directly estimate PP-C. METHODS Invasive high-fidelity right brachial and cent...

متن کامل

Application of the N-point moving average method for brachial pressure waveform-derived estimation of central aortic systolic pressure.

The N-point moving average (NPMA) is a mathematical low-pass filter that can smooth peaked noninvasively acquired radial pressure waveforms to estimate central aortic systolic pressure using a common denominator of N/4 (where N=the acquisition sampling frequency). The present study investigated whether the NPMA method can be applied to brachial pressure waveforms. In the derivation group, simul...

متن کامل

Central versus ambulatory blood pressure in the prediction of all-cause and cardiovascular mortalities.

OBJECTIVES Central systolic (SBP-C) and/or pulse pressure (PP-C) better predicts cardiovascular events than does peripheral blood pressure. The present study compared the prognostic significance of office central blood pressure with multiple measurements of out-of-office ambulatory peripheral blood pressure, with reference to office peripheral systolic (SBP-B) or pulse pressure (PP-B). METHOD...

متن کامل

Quantification of the calibration error in the transfer function-derived central aortic blood pressures.

BACKGROUND The accuracy of the central aortic systolic (SBP-C) and pulse (PP-C) blood pressures estimated noninvasively by a generalized transfer function technique has been questioned. The purpose of the present study was to quantify precisely the impact of the input errors (differences between the oscillometric (SBP-O, DBP-O, PP-O) and invasive (SBP-B, DBP-B, PP-B) brachial systolic, diastoli...

متن کامل

Pulsatile hemodynamics and clinical outcomes in acute heart failure.

BACKGROUND The role of pulsatile hemodynamics in the management of patients with acute heart failure syndrome (AHFS) remains to be elucidated. We investigated the changes of the pulsatile hemodynamics along the hospital course of AHFS in relation to short-term outcomes. METHODS A total of 80 AHFS patients (73.2 ± 14.1 years, 82.5% men) were enrolled and followed up for up to 6 months after di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012