A novel daily QA system for proton therapy

نویسندگان

  • Xiaoning Ding
  • Yuanshui Zheng
  • Omar Zeidan
  • Anthony Mascia
  • Wen Hsi
  • Yixiu Kang
  • Eric Ramirez
  • Niek Schreuder
  • Ben Harris
چکیده

We describe the design and use of a daily quality assurance (QA) system for proton therapy. The QA system is designed to check the overall readiness of proton therapy system consistently within certain reference tolerances by a home-made QA device (the QA device). The QA device is comprised of a commercially available QA device, rf-Daily QA 3, a home-made acrylic phantom, a set of acrylic compensators with various thicknesses, and a mechanical indexing jig. The indexing jig indexes the rf-Daily QA 3, as well as the acrylic phantom, onto the patient treatment couch. Embedded fiducial markers in the acrylic phantom are used to check X-ray image quality and positioning alignment accuracy of the imaging system. The rf-Daily QA 3 is used to check proton beam output, range and symmetry with one single beam delivery. We developed in-house software to calculate beam range and symmetry, based on various ion chambers' readings inside the rf-Daily QA 3. With a single setup and one beam irradiation, the QA system is employed to check couch movement, laser alignment, image registration, and reference proton beam characteristics. The simplicity and robustness of this QA system allows for a total QA time of less than 20 minutes per room. The system has been in use at three proton therapy centers since June 2009.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Daily QA in proton therapy using a single commercially available detector

We present here a novel method for using a single device in the daily quality assur- ance (QA) of pencil beam scanning (PBS) proton beams and an improved method for uniform scanning (US). The device can be used to measure the spot position, spot sigma, range, output, collinearity of the X-ray system and proton beam, and to QA the first scatterers and a number of other imaging and mechanical che...

متن کامل

Investigating Embedded Question Reuse in Question Answering

The investigation presented in this paper is a novel method in question answering (QA) that enables a QA system to gain performance through reuse of information in the answer to one question to answer another related question. Our analysis shows that a pair of question in a general open domain QA can have embedding relation through their mentions of noun phrase expressions. We present methods f...

متن کامل

Dose Assessment of Eye and Its Components in Proton Therapy by Monte Carlo Method

Introduction Proton therapy is used to treat malignant tumors such as melanoma inside the eye. Proton particles are adjusted according to various parameters such as tumor size and position and patient’s distance from the proton source. The purpose of this study was to assess absorbed doses in eyes and various tumors found in the area of sclera and choroid and the adjacent tissues in radiotherap...

متن کامل

Impact of Various Beam Parameters on Lateral Scattering in Proton and Carbon-ion Therapy

Background: In radiation therapy with ion beams, lateral distributions of absorbed dose in the tissue are important. Heavy ion therapy, such as carbon-ion therapy, is a novel technique of high-precision external radiotherapy which has advantages over proton therapy in terms of dose locality and biological effectiveness.Methods: In this study, we used Monte Carlo method-based Geant4 toolkit to s...

متن کامل

A new model for Spread Out Bragg Peak in proton therapy of uveal melanoma

In this research, in order to improve our calculations in treatment planning for proton radiotherapy of ocular melanoma, we improved our human eye phantom planning system in GEANT4 toolkit. Different analytical models have investigated the creating of Spread Out Bragg Peak (SOBP) in the tumor area. Bortfeld’s model is one of the most important analytical methods. Using convolution method, a new...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013