A CMOS active pixel sensor system for laboratory- based x-ray diffraction studies of biological tissue.

نویسندگان

  • Sarah E Bohndiek
  • Emily J Cook
  • Costas D Arvanitis
  • Alessandro Olivo
  • Gary J Royle
  • Andy T Clark
  • Mark L Prydderch
  • Renato Turchetta
  • Robert D Speller
چکیده

X-ray diffraction studies give material-specific information about biological tissue. Ideally, a large area, low noise, wide dynamic range digital x-ray detector is required for laboratory-based x-ray diffraction studies. The goal of this work is to introduce a novel imaging technology, the CMOS active pixel sensor (APS) that has the potential to fulfil all these requirements, and demonstrate its feasibility for coherent scatter imaging. A prototype CMOS APS has been included in an x-ray diffraction demonstration system. An industrial x-ray source with appropriate beam filtration is used to perform angle dispersive x-ray diffraction (ADXRD). Optimization of the experimental set-up is detailed including collimator options and detector operating parameters. Scatter signatures are measured for 11 different materials, covering three medical applications: breast cancer diagnosis, kidney stone identification and bone mineral density calculations. Scatter signatures are also recorded for three mixed samples of known composition. Results are verified using two independent models for predicting the APS scatter signature: (1) a linear systems model of the APS and (2) a linear superposition integral combining known monochromatic scatter signatures with the input polychromatic spectrum used in this case. Cross validation of experimental, modelled and literature results proves that APS are able to record biologically relevant scatter signatures. Coherent scatter signatures are sensitive to multiple materials present in a sample and provide a means to quantify composition. In the future, production of a bespoke APS imager for x-ray diffraction studies could enable simultaneous collection of the transmitted beam and scattered radiation in a laboratory-based coherent scatter system, making clinical transfer of the technique attainable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A ctive P ixel Sensors for breast biopsy analysis using X-ray Diffraction

Breast cancer diagnosis currently requires biopsy samples to be analysed by a histopathologist; a time consuming, highly specialised process. X-ray diffraction is a quantitative technique that can distinguish between healthy and diseased breast biopsy samples using the change in proportions of fat and fibrous tissue that occurs when cancer invades. A semi-automated breast biopsy analysis system...

متن کامل

Introducing an Optimized Method for Obtaining X-ray Diffraction Patterns of Biological Tissues

Introduction Individual X-Ray diffraction patterns of biological tissues are obtained via interference of coherent scattering with their electrons. Many scientists have distinguished normal and cancerous breast tissue, bone density, and urinary stone types using the X-Ray diffraction patterns resulting from coherent scattering. The goal of this study was to introduce an optimized method for obt...

متن کامل

Photon detection with CMOS sensors for fast imaging

Pixel detectors employed in high energy physics, aim at detecting single minimum ionizing particle with micrometric positioning resolution. Monolithic CMOS sensors succeed in this task thanks to a low equivalent noise charge per pixel around 10 to 15 e− and a pixel pitch varying from 10 to a few 10s of microns. Additionally, due to the possibility for integration of some data treatment in the s...

متن کامل

A 96 x 64 Intelligent digital pixel array with extended binary stochastic arithmetic

A chip architecture that integrates an optical sensor and a pixel level processing element based on binary stochastic arithmetic is proposed. The optical sensor is formed by an array of fully connected pixels, and each pixel contains a sensing element and a Pulse Frequency Modulator (PFM) converting the incident light to bit streams of identical pulses. The processing element is based on binary...

متن کامل

New Method for Analysis of image sensor to produce and evaluate the image

In this paper, a new method for evaluating CMOS image sensors based on computer modeling and analysis is introduced. Image sensors are composed of different parts, each of which has a specific effect on image quality. Circuits of image sensors can be evaluated and analyzed using circuit simulators or theoretically, but these methods cannot help to produce the final image. In order to produce th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 53 3  شماره 

صفحات  -

تاریخ انتشار 2008