Tomographic analysis of anatomical parameters of the axis in children
نویسندگان
چکیده
OBJECTIVE To carry out an anatomical study of the axis with the use of computed tomography (CT) in children aged from two to ten years, measuring the lamina angle, lamina and pedicle length and thickness, and lateral mass length. METHODS Sixty-four CTs were studied from patients aged 24 to 120 months old, of both sexes and without any cervical anomaly. The measurements obtained were correlated with the data on age and sex of the patients. Statistical analysis was performed using the Students "t" tests. RESULTS We found that within the age range 24-48 months, 5.5% of the lamina and 8.3% of the pedicles had thicknesses of less than 3.5mm, which is the minimum thickness needed for insertion of the screw. Between 49 and 120 months, there were no lamina thicknesses of less than 3.5mm, and 1.2% of the pedicle thicknesses were less than 3.5mm values. Neither of the age groups had any lamina and pedicle lengths of less than 12mm, or lateral mass lengths greater than 12mm. CONCLUSION The analysis of the data obtained demonstrates that most of the time, is possible to use a 3.5mm pedicle screw in the laminas and pedicles of the axis in children. LEVEL OF EVIDENCE II, Development of diagnostic criteria in consecutive patients.
منابع مشابه
Sinonasal Anatomical Variations: A Multidetector Computed Tomographic Study
Background and Aim: The paranasal sinuses are known for their complex anatomy and significant difference in size and shape. This study aimed to determine the prevalence of anatomical variations of the paranasal sinuses in computed tomography (CT). Materials and Methods: In this cross-sectional study, patients over 18 years of age, who had undergone CT imaging in a private clinic, were screened...
متن کاملComputed Tomographic Anatomy of the Abdominal Cavity in the Jebeer (Gazella Bennettii)
Introduction: Computed tomography (CT) is an imaging technique with gives us an opportunity to review cross sections of the body in live animals. In veterinary medicine although CT is mostly used for diagnostic purposes in small animals, but in recent years CT also has been used as a non invasive modality in non clinical studies. Jebeer Gazelle (Gazella bennettii) is one of the species of the g...
متن کاملDifferent References for Valgus Cut Angle in Total Knee Arthroplasty
Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...
متن کاملAnatomical, radiographical and computed tomographic study of the limbs skeleton of the Euphrates soft shell turtle (Rafetus euphraticus)
Euphrates turtle is the only soft shell turtle of Iran, and unfortunately is in danger of extinction due to multiple reasons. Imaging techniques, in addition to their importance in diagnosis of injuries to animals, have been used as non-invasive methods to provide normal anatomic views. A few studies have been conducted to understand body structure of the Euphrates turtle. Since there is only g...
متن کاملComputed Tomographic Anatomy of the Bronchial Tree of the Jebeer Gazelle
Objectives- to provide a reference anatomy of the bronchial tree of the Jebeer Gazelle by using computed tomographic modality. Design- Experimental study. Animals- Three female Jebeer Gazelle Procedures- Spiral CT images were taken from the thoracic region perpendicular to long axis of the body. CT windows were adjusted as necessary to have optimized images of pulmonary organ. The images ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 20 شماره
صفحات -
تاریخ انتشار 2012