High-reflectivity Cr/Sc multilayer condenser for compact soft x-ray microscopy

نویسنده

  • H. Stollberg
چکیده

The condenser is a critical component in compact water-window x-ray microscopes as it influences the exposure time via its efficiency and the resolution via its numerical aperture. Normal-incidence multilayer mirrors can reach large geometrical collection efficiencies and match the numerical aperture of the zone plate but require advanced processing for high total reflectivity. In the present article we demonstrate large-diameter normal-incidence spherical Cr/Sc multilayer condensers with high and uniform reflectivity. Dc-magnetron sputtering was used to deposit 300 bilayers of Cr/Sc with a predetermined d-spacing matching the =3.374 nm operating wavelength on spherical substrates. The mirrors show a uniform reflectivity of 3% over the full 58 mm diameter condenser area. With these mirrors an improvement in exposure time by a factor of 10 was achieved, thereby improving the performance of the compact x-ray microscope significantly. © 2006 American Institute of Physics. DOI: 10.1063/1.2400665

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Growth and Nano-structural Studies of Metallic Multilayers for X-ray Mirrors

A part of the Ph.D. project focused on growth and characterization of metal multilayers is presented in this licentiate thesis. The main interest in carrying out this research is to develop highly reflective normal-incidence condenser mirrors for soft X-ray microscopy studies in the water window (λ = 2.4− 4.2 nm) wavelength regime. Transition metals like Sc, Ti V, etc. have been considered beca...

متن کامل

Enhanced soft x-ray reflectivity of CrÕSc multilayers by ion-assisted sputter deposition

J. Birch Linköping University Department of Physics Thin Film Division S-58183 Linköping, Sweden Abstract. Cr/Sc multilayers have been grown on Si substrates using dc magnetron sputtering. The multilayers are intended as condenser mirrors in a soft x-ray microscope operating at the wavelength 3.374 nm. They were designed for normal reflection of the first and second orders, with multilayer peri...

متن کامل

14.5% near-normal incidence reflectance of Cr/Sc x-ray multilayer mirrors for the water window.

Cr/Sc multilayer mirrors, synthesized by ion-assisted magnetron sputter deposition, are proved to have a high near-normal reflectivity of R = 14.5% at a grazing angle of 87.5 degrees measured at the wavelength lambda = 3.11 nm, which is an improvement of more than 31% compared with previously published results. Elastic recoil detection analyses show that the mirrors contained as much as 15 at. ...

متن کامل

Compact water-window transmission X-ray microscopy.

We demonstrate sub-100 nm resolution water-window soft X-ray full-field transmission microscopy with a compact system. The microscope operates at lambda = 3.37 nm and is based on a 100 Hz table-top regenerative debris-free droplet-target laser-plasma X-ray source in combination with normal-incidence multilayer condenser optics for sample illumination. High-spatial-resolution imaging is performe...

متن کامل

Measurements of the Optical Constants of Scandium in the 50-1300eV Range

Scandium containing multilayers have been produced with very high reflectivity in the soft x-ray spectrum. Accurate optical constants are required in order to model the multilayer reflectivity. Since there are relatively few measurements of the optical constants of Scandium in the soft x-ray region we have performed measurements over the energy range of 50-1,300 eV. Thin films of Scandium were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006