Pii: S0301-5629(01)00421-5
نویسندگان
چکیده
Using catheter-mounted 2-D array transducers, we have obtained real-time 3-D intracardiac ultrasound (US) images. We have constructed several transducers with 64 channels inside a 12 French catheter lumen operating at 5 MHz. The transducer configuration may be side-scanning or beveled, with respect to the long axis of the catheter lumen. We have also included six electrodes to aquire simultaneous electrocardiograms. Using an open-chest sheep model, we inserted the catheter into the cardiac chambers to study the utility of in vivo intracardiac 3-D scanning. Images obtained include a cardiac four-chamber view, mitral valve, pulmonic valve, tricuspid valve, interatrial septum, interventricular septum and ventricular volumes. We have also imaged two electrophysiological interventional devices in the right atrium, performed an in vitro ablation study, and viewed the pulmonary veins in vitro. (E-mail: [email protected]) © 2001 World Federation for Ultrasound in Medicine & Biology.
منابع مشابه
Pii: S0301-5629(01)00472-0
The nonstationary variation in the noise performance of the cross-correlation-based strain estimator due to frequency-dependent attenuation and lateral and elevational signal decorrelation have been addressed theoretically in recent papers using the strain-filter approach. In this paper, we present the experimental verification and corroboration of the nonstationary effects on the strain estima...
متن کاملPii: S0301-5629(01)00510-5
In conventional elastography, strain is estimated from the gradient of the displacement (time-delay) estimates. The displacement estimates involve estimating the peak location of the cross-correlation function between matching preand post-compression A-lines. Bias errors in estimating the peak location of the cross-correlation function, amplified by the gradient operation on the displacement es...
متن کاملPii: S0301-5629(01)00478-1
In this paper we propose a novel feature-based contrast enhancement approach to enhance the quality of noisy ultrasound (US) images. Our approach uses a phase-based feature detection algorithm, followed by sparse surface interpolation and subsequent nonlinear postprocessing. We first exploited the intensity-invariant property of phase-based acoustic feature detection to select a set of relevant...
متن کاملPii: S0301-5629(01)00442-2
Elastic properties of tendon were assessed by two different approaches. Six fresh bovine Achilles tendon specimens were used. The first approach directly measured Young’s modulus along the transverse direction (Eperpendicular) and the longitudinal direction (Eparallel), using a cyclic compression–relaxation method. Young’s moduli were derived based on the measured strain and stress values. The ...
متن کاملPii: S0301-5629(01)00411-2
This study consisted of two parts. In the first part, the contrast-transfer efficiency (CTE) in elastography was extended to account for continuous changes of modulus distribution. It was shown that, for a finite size background, the strain contrast approaches the modulus contrast in the case of Gaussian distributions. Thus, an increase in the CTE was obtained. For a fixed background size, it w...
متن کامل