Reply to comment on “The use of CR-39 in Pd/D co-deposition experiments”: a response to Kowalski

نویسندگان

  • P. A. Mosier-Boss
  • S. Szpak
  • F. E. Gordon
چکیده

Earlier we reported, in this journal, that the pits generated in CR-39 detectors during Pd/D co-deposition experiments are consistent with those observed for pits that are of a nuclear origin. Recently, that interpretation has been challenged. In this communication, additional experimental data and further analysis of our earlier results are provided that support our original conclusions. PACS. 29.30.Ep Charged-particle spectroscopy – 29.40.Wk Solid-state detectors

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of CR-39 in Pd/D co-deposition experiments

The use of CR-39, a solid state nuclear track detector, to detect the emission of energetic charged particles during Pd/D co-deposition is demonstrated. The pits observed in the CR-39 are attributed to the Pd/D cathode and are not due to radionuclide contamination in the cell components; nor to the impingement of D2 bubbles on the surface of the CR-39; nor to chemical attack by D2, O2, or Cl2. ...

متن کامل

Theoretical interpretation of anomalous tritium and neutron productions during Pd/D co-deposition experiments

The recent experimental observations of triple tracks in solid-state nuclear track detectors, CR-39, during Pd/D co-deposition experiments indicate that the triple tracks are due to∼14 MeV neutrons, which appear to originate from “hot” fusion reaction D(t,n)He. Nuclear theory interpretation of the origin of ∼14 MeV neutrons is presented in terms of a sub-threshold resonance reaction involving (...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

Radically Questioning the Principle of the Least Restrictive Alternative: A Reply to Nir Eyal; Comment on “Nudging by Shaming, Shaming by Nudging”

In his insightful editorial, Nir Eyal explores the connections between nudging and shaming. One upshot of his argument is that we should question the principle of the least restrictive alternative in public health and health policy. In this commentary, I maintain that Eyal’s argument undermines only a rather implausible version of the principle of the least restrictive alternative and I sketch ...

متن کامل

Improving Gas Sensing Properties of Tin Oxide Nanowires Palladium-Coated Using a Low Cost Technique

Thin films of SnO2 nanowires were successfully prepared by using chemical vapor deposition (CVD) process on quartz substrates. Afterwards, a thin  layer of palladium (Pd) as a catalyst was coated on top of nanowires. For the deposition of Pd, a simple and low cost technique of spray pyrolysis was employed, which caused an intensive enhancement on the sensing response of fabricated sensors...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008