Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles

نویسندگان

  • Sung-Hwan Choi
  • Seong-Jin Kim
  • Kee-Joon Lee
  • Sang-Jin Sung
  • Youn-Sic Chun
  • Chung-Ju Hwang
چکیده

OBJECTIVE The purpose of this study was to analyze stress distributions in the roots, periodontal ligaments (PDLs), and bones around cylindrical and tapered miniscrews inserted at different angles using a finite element analysis. METHODS We created a three-dimensional (3D) maxilla model of a dentition with extracted first premolars and used 2 types of miniscrews (tapered and cylindrical) with 1.45-mm diameters and 8-mm lengths. The miniscrews were inserted at 30°, 60°, and 90° angles with respect to the bone surface. A simulated horizontal orthodontic force of 2 N was applied to the miniscrew heads. Then, the stress distributions, magnitudes during miniscrew placement, and force applications were analyzed with a 3D finite element analysis. RESULTS Stresses were primarily absorbed by cortical bone. Moreover, very little stress was transmitted to the roots, PDLs, and cancellous bone. During cylindrical miniscrew insertion, the maximum von Mises stress increased as insertion angle decreased. Tapered miniscrews exhibited greater maximum von Mises stress than cylindrical miniscrews. During force application, maximum von Mises stresses increased in both groups as insertion angles decreased. CONCLUSIONS For both cylindrical and tapered miniscrew designs, placement as perpendicular to the bone surface as possible is recommended to reduce stress in the surrounding bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite element analysis of miniscrew placement in mandibular alveolar bone with varied angulations.

SUMMARY BACKGROUND Titanium miniscrews are increasingly used as orthodontic anchorage. Various factors are known to affect the stability of miniscrew. Placement angle is one of the most controversial issues in this area. Thus, the aim of this finite element study was to evaluate the influence of placement angle and direction of force on the stability of miniscrews. MATERIALS AND METHODS Finit...

متن کامل

A study of interleukin 1β levels in peri-miniscrew crevicular fluid (PMCF)

BACKGROUND This study provides a vital insight in assessing the clinical and biochemical changes in interleukin (IL)-1β levels in peri-miniscrew crevicular fluid (PMCF) during the course of orthodontic tooth movement. METHODS The study comprised the analysis of IL-1β in peri-miniscrew crevicular fluid obtained from crevices around the miniscrews inserted in 11 patients (eight females and thre...

متن کامل

A miniplate system for improved stability of skeletal anchorage.

miniscrews reportedly have failure rates as high as 10-30%.1-4 Miniscrew loosening or tipping can result from any of the following factors: • Insufficient bone quantity or quality at the insertion site.5-7 • Use of a screw of inadequate diameter or length.3,8-10 • Inappropriate intraosseous design.10-12 • Root contact during insertion.13 • Manipulation by the patient’s fingers or tongue.8 • Poo...

متن کامل

Evaluation of the Effects of Different Surface Configurations on Stability of Miniscrews

INTRODUCTION The aim of this study was to analyze the effects of screw design and force application on the stability of miniscrews, using RTT, SEM, and histomorphometric analyses. MATERIALS AND METHODS Eighty cylindrical, self-drilling, and Ti6Al4V alloy miniscrews (1,6 × 6 mm) were used. Four mini-screws were inserted in fibulas of each rabbit, and 115 G of force was immediately applied. Fou...

متن کامل

Optimal palatal configuration for miniscrew applications.

OBJECTIVE To test the hypothesis that palatal bone is not able to support titanium miniscrews (11 mm in length and 2 mm in diameter) when subjected to forces normally generated during orthodontic treatment. MATERIALS AND METHODS The miniscrew-palatal bone system was modeled and analyzed using the commercial finite element method software ANSYS Multiphysics 10.0; tests were done in both a stat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2016