Carr-Purcell-Meiboom-Gill train of radiofrequency pulses applied to spins in the constant magnetic field gradient is an efficient variant of the modulated magnetic field gradient spin echo method, which provides information about molecular diffusion in the frequency-domain instead in the time-domain as with the two-pulse gradient spin echo. The frequency range of novel technique is broad enough to sample the power spectrum of displacement fluctuation in water-saturated pulverized silica (SiO(2)) and provides comprehensive information about the molecular restricted motion as well as about the structure of medium.
منابع مشابه
Magnetic Resonance Spectral Characterization of Diffusion with Chemical Shift Resolution
We present a modulated gradient spin-echo method (MGSE), which uses a train of sinusoidally shaped gradient pulses separated by 180-degree RF pulses. The RF pulses efficiently refocus chemical shifts and de-phasing due to susceptibility differences, resulting in undistorted, high-resolution diffusion weighted spectra. This allows for simultaneous spectral characterization of diffusion of severa...
متن کاملDisplacement power spectrum measurement by CPMG in constant gradient.
The modulation of spin phase produced by Carr-Purcell-Meiboom-Gill (CPMG) sequence in combination with constant magnetic field gradient is appropriate to probe the displacement power spectrum (DPS). The spin-echo attenuation is directly proportional to the DPS value at the applied modulation frequency. Relaxation and selective excitation effects can be factored out while probing the DPS. The mo...
متن کاملThe elimination of magnetic susceptibility artifacts in the micro-image of liquid-solid interfaces: internal gradient modulation by the CPMG RF train.
Distortions of magnetic resonance images near solid-liquid interface appear as the result of the restriction to spin self-diffusion in the proximity of impermeable boundary as well as of a susceptibility difference. The spectral analysis of spin echo enables to resolve, in a simple way, how various RF-gradient pulse sequences reduce the effect of the internal magnetic field induced by the susce...
متن کاملMultiplex RARE Dixon: a novel multislice RARE sequence applied to simultaneous slice fat-water Dixon imaging
Introduction Multislice excitation methods have been widely used to increase efficiency in volume coverage. In the simultaneous spin-echo refocusing sequence (SER) [1], two or more slices are excited simultaneously and refocused with a train of 180° pulses which act simultaneously on both slices. However, the SER sequence does not fulfil CPMG conditions, and requires special spoiler gradients t...
متن کاملPROPELLER DUO: Applied to Diffusion-Weighted Imaging
Introduction: Fast Spin Echo (FSE) could suffer from the non-CPMG condition that results in destructive echo interference, unstable echo train and signal cancellation. Diffusion-weighted (DW) PROPELLER [1], an FSE-based sequence, mitigates the non-CPMG issue by XY phase cycling [1] combined with split-blade acquisition [2]. However, XY phase cycling requires refocus flip angle be close to 180° ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance
دوره 182 2 شماره
صفحات -
تاریخ انتشار 2006