Testing a novel method for measuring sleeping metabolic rate in neonates.
نویسندگان
چکیده
BACKGROUND Sleeping metabolic rate (SMR) is used as a proxy for basal metabolic rate in infants, when measurement while awake is not practical. Measuring SMR via indirect calorimetry (IC) can be useful for assessing feeding adequacy especially in compromised neonates. Standard IC equipment, including a hood placed over the head, is not designed for the smallest of patients. Our aim was to determine whether a nonstandard smaller hood measures SMR in neonates similarly compared with a standard large hood. METHODS SMR was measured in healthy neonates (controls) and those born with single-ventricle congenital heart disease (cases). Two measurements were performed: SMR using a standard large hood and SMR using a smaller hood. Time-to-steady state, minute ventilation (V̇E), and fraction of exhaled carbon dioxide (FĒCO2 ; an indicator of data quality) were also measured. Primary outcome was SMR using both hoods. Results are stated as median (interquartile range). Spearman's correlations measured association between the small and large hoods. RESULTS We studied 9 controls and 7 cases. SMR in controls was not different between the small and large hoods (35.7 [15.14] vs 37.8 [7.41] kcal/kg/d, respectively). In cases, SMR with the small hood was significantly greater than that with the large hood (45.5 [4.63] vs 34.2 [8] kcal/kg/d, P < .02). FĒCO2 was significantly higher with the small hood versus the large hood in both groups, and V̇E was significantly lower with the small hood versus the large hood in controls only. The SMRs with the small and large hoods were significantly correlated in the control group (r = 0.80, P < .01). Time-to-steady state was similar in both groups regardless of hood size. CONCLUSIONS SMR measured with a small hood yields results similar to those measured with a large hood in healthy neonates without affecting testing time or other aspects of the IC procedure. Furthermore, results in compromised infants suggest that a smaller hood may facilitate SMR testing in this population.
منابع مشابه
A Novel Fuzzy Based Method for Heart Rate Variability Prediction
Abstract In this paper, a novel technique based on fuzzy method is presented for chaotic nonlinear time series prediction. Fuzzy approach with the gradient learning algorithm and methods constitutes the main components of this method. This learning process in this method is similar to conventional gradient descent learning process, except that the input patterns and parameters are stored in mem...
متن کاملکمیت و کیفیت خواب و ارتباط آن با سندرم متابولیک
Background and purpose: Sleep is one the main physiological parameters in circadian rhythm. Poor sleep is associated with many health consequences such as increased overall mortality and metabolic syndrome in adults and children. The aim of this study was to investigate the relationship between sleep and metabolic syndrome. Materials and methods: In a descriptive study, data of 2038 participan...
متن کاملA novel approach to calculating the thermic effect of food in a metabolic chamber
The thermic effect of food (TEF) is the well-known concept in spite of its difficulty for measuring. The gold standard for evaluating the TEF is the difference in energy expenditure between fed and fasting states (ΔEE). Alternatively, energy expenditure at 0 activity (EE0) is estimated from the intercept of the linear relationship between energy expenditure and physical activity to eliminate ac...
متن کاملA Novel Method for Measuring, Regardless of Image Distortion and Lens Varying Specifications in Endoscopic Treatment of Vesicoureteral Reflux
متن کامل
Thickness Measuring of Thin Metal by Non Destructive with Fuzzy Logic Control System
Non-Destructive Testing & Evaluation methods are developed to inspect and investigate materials and structures. Ultrasonic Testing is an NDT method can be used for measuring the thickness of objects, as one of its significant applications. The objective of this paper is designing and applying an intelligent UT fuzzy control system for evaluating the thickness of thin metal objects in a range of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 59 7 شماره
صفحات -
تاریخ انتشار 2014