Impedance cardiography: Pulsatile blood flow and the biophysical and electrodynamic basis for the stroke volume equations

نویسنده

  • Donald P. Bernstein
چکیده

Impedance cardiography (ICG) is a branch of bioimpedance primarily concerned with the determination of left ventricular stroke volume (SV). As implemented, using the transthoracic approach, the technique involves applying a current field longitudinally across a segment of thorax by means of a constant magnitude, high frequency, low amplitude alternating current (AC). By Ohm’s Law, the voltage difference measured within the current field is proportional to the electrical impedance Z (Ω). Without ventilatory or cardiac activity, Z is known as the transthoracic, static base impedance Z0. Upon ventricular ejection, a characteristic time dependent cardiac-synchronous pulsatile impedance change is obtained, ∆Z(t), which, when placed electrically in parallel with Z0, constitutes the time-variable total transthoracic impedance Z(t). ∆Z(t) represents a dual-element composite waveform, which comprises both the radially-oriented volumetric expansion of and axially-directed forward blood flow within both great thoracic arteries. In its majority, however, ∆Z(t) is known to primarily emanate from the ascending aorta. Conceptually, commonly implemented methods assume a volumetric origin for the peak systolic upslope of ∆Z(t), (i.e. dZ/dtmax), with the presumed units of Ω·s. A recently introduced method assumes the rapid ejection of forward flowing blood in earliest systole causes significant changes in the velocity-induced blood resistivity variation (∆ρb(t), Ωcm·s), and it is the peak rate of change of the blood resistivity variation dρb(t)/dtmax (Ωcm·s) that is the origin of dZ/dtmax. As a consequence of dZ/dtmax peaking in the time domain of peak aortic blood acceleration, dv/dtmax (cm·s), it is suggested that dZ/dtmax is an ohmic mean acceleration analog (Ω·s) and not a mean flow or velocity surrogate as generally assumed. As conceptualized, the normalized value, dZ/dtmax/Z0, is a dimensionless ohmic mean acceleration equivalent (s), and more precisely, the electrodynamic equivalent of peak aortic reduced average blood acceleration (PARABA, d/dtmax/R, s). As necessary for stroke volume calculation, dZ/dtmax/Z0 must undergo square root transformation to yield an ohmic mean flow velocity equivalent. To compute SV, the square root of the dimensionless ohmic mean acceleration equivalent ([dZ/dtmax/Z0], s) is multiplied by a volume of electrically participating thoracic tissue (VEPT, mL) and left ventricular ejection time (TLVE, s). To find the bulk volume of the thoracic contents (i.e. VEPT), established methods implement exponential functions of measured thoracic length (L(cm)) or height-based thoracic length equivalents (0.01×%H(cm)). The new method conceptualizes VEPT as the intrathoracic blood volume (ITBV, mL), which is approximated through allometric equivalents of body mass (aM). In contrast to the classical twoelement parallel conduction model, the new method comprises a three-compartment model, which incorporates excess extravascular lung water (EVLW) as a component of both Z0 and VEPT. To fully appreciate the evolution and analytical justification for impedance-derived SV equations, a review of the basics of pulsatile blood flow is in order.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior-posterior impedance cardiography: a new approach to accurate, non-invasive monitoring of cardiac function.

The conventional impedance cardiogram is a record of pulsatile changes in the electrical impedance of the chest with each heartbeat. The signal seems intuitively related to cardiac stroke volume. However doubts persist about the validity of stroke volume measurements based on electrical impedance. This paper presents a new electrical axis for impedance cardiography that is perpendicular to the ...

متن کامل

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

Newtonian and Non-Newtonian Blood Flow Simulation after Arterial Stenosis- Steady State and Pulsatile Approaches

Arterial stenosis, for example Atherosclerosis, is one of the most serious forms of arterial disease in the formation of which hemodynamic factors play a significant role. In the present study, a 3-D rigid carotid artery with axisymmetric stenosis with 75% reduction in cross-sectional area is considered. Laminar blood flow is assumed to have both Newtonian and non-Newtonian behavior (generalize...

متن کامل

Standardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilution.

Since its introduction by Kubicek and colleagues, impedance cardiography has been suggested as a non-invasive, simple, safe and cost-effective method of measuring stroke volume. Several controversial reports on its validity have been published. Pitfalls of this method included the nature of the electrode system and the validity of the equations. Therefore, the purpose of this study was to compa...

متن کامل

An implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery

With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009