A method to estimate dispersion in sampling catheters and to calculate dispersion-free blood time-activity curves.

نویسندگان

  • Ole Lajord Munk
  • Susanne Keiding
  • Ludvik Bass
چکیده

The authors developed a transmission-dispersion model to estimate dispersion in blood sampling systems and to calculate dispersion-free input functions needed for kinetic analysis. Transport of molecules through catheters was considered in two parts: a central part with convective transmission of molecules and a stagnant layer that molecules may enter and leave. The authors measured dispersion caused by automatic and manual blood sampling using three PET tracers that distribute differently in blood (C15O, H2(15)O, and 11C-methylglucose). For manual sampling, dispersion was negligible. For the automated sampling procedure, characteristic parameters were calibrated for each tracer, and subsequently used in calculating dispersion-free input functions following real bolus injections. This led to shapes of dispersion-free input functions C(i)(t) that had sharper peaks than the measured C(o)(t), and the authors quantified the effect of correcting for dispersion before kinetic modeling. The transmission-dispersion model quantitatively takes apart effects of transmission and dispersion, it has transparent noise properties associated with each component, and it does not require deconvolution to calculate dispersion-free input functions. Once characteristic parameters are estimated, input functions can be corrected before applying kinetic models. This allows bias-free estimation of kinetic parameters such as blood flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Joint inversion of ReMi dispersion curves and refraction travel times using particle swarm optimization algorithm

Shear-wave velocity ( ) is an important parameter used for site characterization in geotechnical engineering. However, dispersion curve inversion is challenging for most inversion methods due to its high non-linearity and mix-determined trait. In order to overcome these problems, in this study, a joint inversion strategy is proposed based on the particle swarm optimization (PSO) algorithm. The ...

متن کامل

بررسی آزمایشگاهی اثر روش نمونه‌برداری در آزمایش‌های ردیابی بر ضریب انتشارپذیری آبخوان

Tracer experiments are very important in the studies related to aquifer contamination for determination of dispersion coefficient. In this study, the effect of sampling method on the dispersion coefficients of two simulated sandy aquifers was examined. The physical model was made from Plexiglas material with inner length, width and height of 72, 10 and 120 cm, respectively. A solution containin...

متن کامل

بررسی آزمایشگاهی اثر روش نمونه‌برداری در آزمایش‌های ردیابی بر ضریب انتشارپذیری آبخوان

Tracer experiments are very important in the studies related to aquifer contamination for determination of dispersion coefficient. In this study, the effect of sampling method on the dispersion coefficients of two simulated sandy aquifers was examined. The physical model was made from Plexiglas material with inner length, width and height of 72, 10 and 120 cm, respectively. A solution containin...

متن کامل

Impact of Blood Vessel Wall Flexibility on the Temperature and Concentration Dispersion

The analysis of solute and thermal dispersion in pulsatile flow through the stenotic tapered blood vessel is presented. The present problem is an extension of the work done by Ramana et al. who considered the time-invariant arterial wall. In the present model, the flexible nature of the arterial wall through the obstruction (called stenosis) is considered and it is achieved with the he...

متن کامل

Dispersion Coefficients of Supercritical Fluid in Fixed Beds

The axial dispersion coefficient of hexachlorobenzene in supercritical carbon dioxide is investigated in a fixed-bed packed with glass beads. The on-line chromatographic pulse-response experiment is used in order to study the dynamics of a packed column under supercritical conditions. The radial dispersion is assumed negligible because of the packed column geometry. To estimate the axial disper...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 35 8  شماره 

صفحات  -

تاریخ انتشار 2008