Bulk motion-independent analyses of water diffusion changes in the brain during the cardiac cycle.
نویسندگان
چکیده
We evaluated dynamic changes in water diffusion in the brain during the cardiac cycle by using cine diffusion MRI. On a 1.5-T MRI, ECG-triggered single-shot diffusion echo planar imaging was used with sensitivity encoding, halfscan, and rectangular field of view techniques for minimizing bulk motion effects such as brain pulsation, with a data-sampling window of 3 ms. The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) in the white matter zone were determined in ten healthy volunteers and then compared with the intracranial volume change (ICVC) revealed by phase-contrast cine MRI during the cardiac cycle. In addition, a frequency analysis of these waveforms was performed. ADC and FA values changed significantly during the cardiac cycle, despite minimizing the effect of bulk motion, i.e., independent of bulk motion. The ADC was synchronized with the ICVC during the cardiac cycle. A significant positive correlation was noted among their amplitudes. Analysis of the dynamic change of water diffusion by use of cine diffusion MRI facilitates the assessment of intracranial conditions.
منابع مشابه
Bulk - motion - independent analyses of water diffusion change in the brain during the cardiac cycle
متن کامل
اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدلسازی منحنی چند جمله ای
Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...
متن کاملReducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
متن کاملAn advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries
Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...
متن کاملCardiac diffusion MRI without motion effects.
We present a method for diffusion tensor MRI in the beating heart that is insensitive to cardiac motion and strain. Using a stimulated echo pulse sequence with two electrocardiogram (ECG) triggers, diffusion-encoding bipolar gradient pulses are applied at identical phases in consecutive cardiac cycles. In this experiment, diffusion is encoded at a single phase in the cardiac cycle of less than ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiological physics and technology
دوره 2 2 شماره
صفحات -
تاریخ انتشار 2009