Inadequate measurement of urinary chloride.
نویسندگان
چکیده
Urinary electrolytes are invaluable in the differential diagnosis and treatment of certain acid-base diseases. We have evaluated the accuracy and precision of three different automated chemistry analyzers and a chloridometer (Corning 925 Chloridometer, Hitachi 717 and 917 and Vitros 950) for chloride, sodium and potassium using standard solutions. Data indicate that the ISE modules on the Hitachi 717 and 917 analyzers measure sodium and potassium accurately and precisely throughout the studied concentration range. The Vitros 950 system had the poorest precision and accuracy performance at the low levels of sodium and potassium. The chloride ion-selective membranes on the Hitachi analyzers seriously overestimate the chloride concentration at all levels. The manual dilution method on the Vitros 950 analyzer for chloride measurements showed good precision and accuracy only at the higher chloride levels. For chloride determination the chloridometer displayed the best accuracy with good precision. We recommend that laboratories use chloridometers for the measurement of urinary chloride, and that the CAP include low chloride samples in their proficiency testing program for urine chloride.
منابع مشابه
Transient Pseudohypoaldosteronism due to Urinary Tract Infection in Infancy: A Report of 4 Cases
Hyponatremia with hyperkalemia in infancy is an uncommon but life-threatening occurrence. In the first weeks of life, this scenario is often associated with aldosterone deficiency due to salt-wasting congenital adrenal hyperplasia. However, alternative diagnoses involving inadequate mineralocorticoid secretion or action must be considered, particularly for infants one month of age or older. We ...
متن کاملApproach to hypokalemia.
Hypokalemia is frequently encountered in clinical practice. It can be due to either potassium deficiency (inadequate potassium intake or excessive potassium loss) or to net potassium shifts from the extracellular to the intracellular compartment. Inadequate dietary intake of potassium alone rarely causes hypokalemia since kidney is able to lower potassium excretion below 15 mmol per day. Hypoka...
متن کاملTreatment of intractable coccygodynia by transsacral ammonium chloride injection.
HE PATIENT with coccygodynia is often T abandoned because of the failure of recommended conservative treatment and the physician’s hesitancy to recommend more radical forms of therapy. Furthermore, mutual dissatisfaction often leaves the patient labeled as neurotic and the physician as inadequate. Both perceptions result from frustration with current therapeutic vogues and handicap continued th...
متن کاملEvaluation of Toluene Exposure in Workers at Industrial Area of Sidoarjo, Indonesia by Measurement of Urinary Hippuric Acid
Background: Toluene is a harmful substance still being used as a solvent and catalyst in many industries that can increase the level of urinary hippuric acid (UHA). This study was designed to examine the level of toluene and UHA among workers of industrial site in seven companies in Sidoarjo, Indonesia and to analyze the risk factors for abnormal UHA. Methods: This study was an analytical cross...
متن کاملThe Quantab strip in the measurement of urinary chloride and sodium concentrations.
The "Quantab" strip (Ames) measures chloride in fluids. For sodium chloride solutions and urine we found very good correlations between the Quantab reading and the chloride concentration as measured by chemical assay (r = 0.95 for chloride and r = 0.85 for sodium in urine). The strip gave reproducible results over the temperature range 4 to 37 degrees C. There was very little inter- and intra-o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of clinical and laboratory science
دوره 28 6 شماره
صفحات -
تاریخ انتشار 1998