Clinical Performance of Toris K Contact Lens in Patients with Moderate to Advanced Keratoconus: A Real Life Retrospective Analysis

نویسندگان

  • Ihsan Yilmaz
  • Ferah Ozcelik
  • Berna Basarir
  • Gokhan Demir
  • Gonul Durusoy
  • Muhittin Taskapili
چکیده

Objectives. To evaluate the visual performance of Toris K soft contact lenses in patients with moderate-to-advanced keratoconus and also to compare the results according to cone types, cone location, and severity of keratoconus. Materials and Methods. Sixty eyes of 40 participants were included in this retrospective study. Uncorrected visual acuity (UCVA), best-spectacle corrected visual acuity (BCVA), best-contact lens corrected visual acuity (BCLCVA), and comfort rating via visual analogue scales (VAS) were measured. Results. The mean age was 27.3 ± 8.6 years (range: 18 to 54). The mean logMAR UCVA, BCVA, and BCLCVA were 0.85 ± 0.38 (range: 0.30-1.30), 0.47 ± 0.27 (range: 0.10-1.30), and 0.16 ± 0.20 (range: 0-1.00). There were significant increases in visual acuities with contact lenses (p < .05). BCLCVA was significantly better in oval type than globus type (p = .022). UCVA and BCLCVA were significantly better in moderate keratoconus group (p = .015, p = .018). The mean line gain in Snellen was 3.6 ± 1.8 lines (range: 0-7 lines). The mean line gain was higher in central cone group than paracentral cone group and oval group than globus group (p = .014, p = .045). The mean VAS score was 8.14 ± 1.88 (range: 6-10). Conclusions. Toris K can improve visual acuity of patients with keratoconus. Toris K is successful even in the moderate and advanced form of the disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Success of hydrocone (TORIS-K) soft contact lens for keratoconus and traumatic keratopathy

OBJECTIVE To present success of Toris-K contact lenses in keratoconus and traumatic keratopathy with irregular corneal surface. METHODS Toris-K contact lenses were used to treat 7 eyes of 4 patients with traumatic keratopathy (Case 1) or keratoconus (Case 2, Case 3, and Case 4). All cases had a complete eye examination before the contact lens application. The case with traumatic keratopathy w...

متن کامل

Hydro cone lens visual performance and impact on quality of life in irregular corneas.

The aim of this study is to evaluate the visual performance (efficiency) of HydroCone (Toris K) soft silicon hydrogel lenses in patients with irregular corneas.

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

A clinical decision support system for contact lens evaluation

Background: Contact lenses are transparent, thin plastic disks that cover the surface of the cornea. Appropriate lens prescription should be performed properly by an expert to provide better visual acuity and reduce side effects. The lens administration is a multi-stage, complex and time-consuming process involving many considerations. The purpose of this study was to develop a decision support...

متن کامل

Descriptive analysis of the type and design of contact lenses fitted according to keratoconus severity and morphology.

PURPOSE Keratoconus is characterized by bilateral asymmetrical corneal ectasia that leads to inferior stromal thinning and corneal protrusion. There is currently a lack of consensus regarding the most efficacious method for fitting contact lenses in patients with keratoconus, given the various topographical patterns and evolution grades observed in affected populations. The purpose of the prese...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016