Evaluation of an improved pneumatic-tube system suitable for transportation of blood specimens.

نویسندگان

  • D A Pragay
  • L Edwards
  • M Toppin
  • R R Palmer
  • M E Chilcote
چکیده

An improved version of a pneumatic-tube system built by Amsco, Inc. (Erie, Pa.) and its subsidiary ATC (San Rafael, Calif.) for blood-sample transportation incorporated two innovations: The sample carrier travels at a lower speed than in the previous conventional systems, and itis decelerated gradually on arrival. This tube system was pilot tested for eff iciency by running blood-filled Vacutainer tubes through the 63.6-rn (210-feet) tube 10 times, a total running distance of 636 m. Serum lactate dehydrogenase and acid phosphatase activities,and potassium, all sensitive chemical indicators of erythrocyte membrane damage, were measured in blood specimens in partially or totally filled Vacutainer tubes and the results compared with those obtained from controls. No alterations were found in serum test results after 10 or 20 repetitive cycles in the totally filled tubes, but significant changes did occur in partially filled tubes after 20 cycles. If the limitations are observed, this system appears to be suitable for blood-specimen transportation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

INTRODUCTION Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. METHODS The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest(®)) for potass...

متن کامل

Delivery of BloodSpecimens

Blood specimens from normal individuals and patients (with and without blood dyscrasias) were sent through a 1,423-m pneumatic-tube system that included two monitoring devices, three switches, and 67 bends (62 with a 152-cm radius and 5 with a 76-cm radius), and then returned to the central laboratory. Each specimen was thus subjected to twice the trauma it usually would receive during transit....

متن کامل

Pseudohyperkalaemia with acute leukaemia: association with pneumatic tube transport of blood specimens.

Falsely elevated serum or plasma potassium level can be the result of mechanical injury to blood cells. We describe pseudohyperkalaemia caused by pneumatic tube transport of blood specimens from a patient with leukaemia. Clinicians should be aware of this possibility when interpreting the clinical significance of hyperkalaemia. In leukaemic patients, pneumatic tube transport of blood specimens ...

متن کامل

Preanalytical errors introduced by sample-transportation systems: a means to assess them.

Sample transportation is one of the major factors contributing to delays in returning high-quality clinical laboratory results to the patient bedside. Furthermore, sample quality can be compromised by exposure to extremes of temperature and physical forces during transportation. Uncontrolled temperature-induced errors are well understood and are often prevented by using environmentally controll...

متن کامل

Effect of blood collection tubes on the incidence of artifactual hyperkalemia on patient samples from an outreach clinic.

BACKGROUND An offsite satellite clinic of the University of Chicago Medical Center (UCMC) requested an investigation by the Clinical Chemistry Laboratory (CCL) into several cases of possible falsely elevated potassium (K⁺) values in their patients. Bloods for K⁺ and chemistry profiles are routinely collected in mint-green, heparinized plasma separator tubes (PST), centrifuged, and transported b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 1974