SU-E-I-39: Experimental Study On the Performance of the OMAR CT Artifact Correction Algorithm Near Titanium and Stainless Steel.

نویسندگان

  • A Schoenfeld
  • R Crilly
  • B Poppe
  • W Laub
چکیده

PURPOSE Implants with high atomic numbers produce star-like artifacts in CT-images. When coupled in pairs, a black window appears in between. The Philips OMAR algorithm approaches these artifacts by post processing the images. In this study, measurements were performed with radiochromic EBT2 films in order to verify, whether the OMAR algorithm contributes to the accuracy of treatment plans in implant regions. METHODS Two sets of titanium and stainless steel rods with diameters of 1inch and 0.5inch were centered in a water phantom either single or in pairs. The phantom was scanned in a Philips Bigbore Brilliance scanner, which provides the OMAR correction algorithm. A set of uncorrected CT data was kept in addition to the post processed data. The treatment plans were calculated with AAA in Eclipse. The Hounsfield units in the volume of the metal rods were set to match the relative electron density with the conversion table extended accordingly. A 10×12 field at 90 degrees gantry rotation and 400MU was calculated using on a 1mm grid. The plans were irradiated using a Varian Novalis-TX linac with EBT3 films placed on the sides of the single rod setup or between the rods in the two rod setups. The FilmQA Pro Software was used for evaluation of the films. RESULTS With one inhomogeneity present in the phantom, the difference between the plans based on the uncorrected data and the plans based on the post processed data is small. With paired inhomogeneities and the associated increased artifact, the difference becomes more significant and the OMAR algorithm improves the accuracy. High Z scattering effects cause considerable deviation from the planned dose profiles near the rods. CONCLUSION The OMAR-algorithm improves the accuracy of the dose calculations. The dose profiles across implant regions are calculated accurately, if the Hounsfield units are defined accordingly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study

Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...

متن کامل

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

A review of the requirements and hazards of toxic metals from orthodontic wires

Background: Orthodontics is a part of dentistry that includes preventive methods and correction of dental irregularities that need to be repositioned by functional and mechanical tools to provide an ideal occlusion and a beautiful face for patients. There are currently four metal arch wires used in orthodontic treatment: stainless steel alloy, cobalt-chromium alloy, nickel-titanium alloy, and b...

متن کامل

Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends

  The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...

متن کامل

Vacuum Brazing of Zirconium-Based Alloy and 321 Stainless Steel Using Titanium Based Filler Metal

Both Zirconium-based alloys and 321stainless steel are widely used as engineering alloys due to their good mechanical properties. Conventional fusion welding techniques for Zr alloys and stainless steel are not feasible due to the formation of brittle intermetallic compounds such as (Zr3Fe, ZrFe2 and Zr2Fe) and corrosion cracking. Brazing is one of the most wide...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 40 6Part5  شماره 

صفحات  -

تاریخ انتشار 2013