Correlation between HIV-1 viral load quantification in plasma, dried blood spots, and dried plasma spots using the Roche COBAS Taqman assay.
نویسندگان
چکیده
BACKGROUND The use of simplified methods for viral load determination could greatly increase access to treatment monitoring of HIV patients in resource-limited countries. OBJECTIVE The aim of the present study was to optimize and evaluate the performance of the Roche COBAS Taqman assay in HIV-RNA quantification from dried blood spots (DBS) and dried plasma spots (DPS). STUDY DESIGN EDTA blood samples from 108 HIV-infected women were used to prepare 129 DBS and 76 DPS on Whatman 903 card. DBS and DPS were stored at -20 degrees C. HIV-1 RNA was extracted from DBS/DPS using the MiniMAG system (bioMerieux). Amplification and detection were performed using the Roche COBAS TaqMan assay. Plasma viral load results were used as standard. RESULTS There was a high correlation between measures of viral load in plasma and in DBS/DPS (r=0.96 and 0.85 respectively, P<0.001). Overall, viral load values in DBS and DPS tended to be lower than in plasma with mean (SD) differences of 0.32 log(0.22) for DBS and of 0.35 (0.33) for DPS. Detection rates were 96.4% for DBS and 96.1% for DPS in samples with corresponding plasma values >3.0 log copies/ml. Samples with HIV-RNA below 50 copies/ml were correctly identified in 18/19 DBS and in 7/7 DPS. CONCLUSIONS Both DBS and DPS provided results highly correlated to the plasma values. High detection rate was obtained with both DBS and DPS when HIV-RNA was >3.0 log copies/ml. Our results support the use of DBS/DPS to detect virologic failure in resource-limited settings.
منابع مشابه
Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya
BACKGROUND Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood s...
متن کاملDetermination of HIV-1 viral load on dried blood spot specimens
Dried blood spot specimens on filter paper were evaluated to determine the viral load of the human immunodeficiency virus type 1 (HIV-1), through the Cobas®Ampliprep/Cobas®Taqman® HIV-1 test. RNA levels were quantified in pairs of plasma and dry blood spot specimens on filter paper from persons infected with HIV-1. The Pearson linear correlation coefficient was calculated as well as the agreeme...
متن کاملEvaluation of quantification of HIV-1 RNA viral load in plasma and dried blood spots by use of the semiautomated Cobas Amplicor assay and the fully automated Cobas Ampliprep/TaqMan assay, version 2.0, in Kisumu, Kenya.
In Kenya, HIV-1 viral load monitoring is commonly performed with the Cobas Amplicor using plasma specimens. Interest is growing in transitioning to real-time PCR (RT-PCR), such as the Cobas Ampliprep/Cobas TaqMan (CAP/CTM), using dried blood spots (DBS). Before implementation, direct evaluation of the two assays using DBS field specimens is required. This study compares the sensitivity, specifi...
متن کاملA Simple Phosphate-Buffered-Saline-Based Extraction Method Improves Specificity of HIV Viral Load Monitoring Using Dried Blood Spots
Although Roche COBAS Ampliprep/COBAS TaqMan (CAP/CTM) systems are widely used in sub-Saharan Africa for early infant diagnosis of HIV from dried blood spots (DBS), viral load monitoring with this system is not practical due to nonspecific extraction of both cell-free and cell-associated viral nucleic acids. A simplified DBS extraction technique for cell-free virus elution using phosphate-buffer...
متن کاملQuantification of HIV-RNA from dried blood spots using the Siemens VERSANT® HIV-1 RNA (kPCR) assay.
OBJECTIVES Simplified methods for virological monitoring in resource-limited settings are increasingly needed. We evaluated the performance of the VERSANT(®) HIV-1 RNA (kPCR) assay for the determination of HIV-1 viral load from dried blood spots (DBS). Assay sensitivity and correlation with plasma quantification values were assessed. METHODS A total of 98 DBS were prepared from fresh blood sa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology
دوره 47 1 شماره
صفحات -
تاریخ انتشار 2010