Programming Cardiac Resynchronization Therapy for Electrical Synchrony: Reaching Beyond Left Bundle Branch Block and Left Ventricular Activation Delay

نویسندگان

  • Niraj Varma
  • David O'Donnell
  • Mohammed Bassiouny
  • Philippe Ritter
  • Carlo Pappone
  • Jan Mangual
  • Daniel Cantillon
  • Nima Badie
  • Bernard Thibault
  • Brian Wisnoskey
چکیده

BACKGROUND QRS narrowing following cardiac resynchronization therapy with biventricular (BiV) or left ventricular (LV) pacing is likely affected by patient-specific conduction characteristics (PR, qLV, LV-paced propagation interval), making a universal programming strategy likely ineffective. We tested these factors using a novel, device-based algorithm (SyncAV) that automatically adjusts paced atrioventricular delay (default or programmable offset) according to intrinsic atrioventricular conduction. METHODS AND RESULTS Seventy-five patients undergoing cardiac resynchronization therapy (age 66±11 years; 65% male; 32% with ischemic cardiomyopathy; LV ejection fraction 28±8%; QRS duration 162±16 ms) with intact atrioventricular conduction (PR interval 194±34, range 128-300 ms), left bundle branch block, and optimized LV lead position were studied at implant. QRS duration (QRSd) reduction was compared for the following pacing configurations: nominal simultaneous BiV (Mode I: paced/sensed atrioventricular delay=140/110 ms), BiV+SyncAV with 50 ms offset (Mode II), BiV+SyncAV with offset that minimized QRSd (Mode III), or LV-only pacing+SyncAV with 50 ms offset (Mode IV). The intrinsic QRSd (162±16 ms) was reduced to 142±17 ms (-11.8%) by Mode I, 136±14 ms (-15.6%) by Mode IV, and 132±13 ms (-17.8%) by Mode II. Mode III yielded the shortest overall QRSd (123±12 ms, -23.9% [P<0.001 versus all modes]) and was the only configuration without QRSd prolongation in any patient. QRS narrowing occurred regardless of QRSd, PR, or LV-paced intervals, or underlying ischemic disease. CONCLUSIONS Post-implant electrical optimization in already well-selected patients with left bundle branch block and optimized LV lead position is facilitated by patient-tailored BiV pacing adjusted to intrinsic atrioventricular timing using an automatic device-based algorithm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electromechanical model of cardiac resynchronization in the dilated failing heart with left bundle branch block.

Experimental studies have shown that biventricular pacing can improve systolic function in the failing heart with bundle branch block. The goal of this study was to develop and validate a three-dimensional computational model of the dilated failing heart with left bundle branch block to investigate how biventricular pacing can improve systolic mechanical performance and synchrony. In an anatomi...

متن کامل

Electrical and mechanical components of dyssynchrony in heart failure patients with normal QRS duration and left bundle-branch block: impact of left and biventricular pacing.

BACKGROUND Resynchronization pacing is an effective symptomatic treatment for heart failure patients with prolongation of the QRS duration (QRSd). Dyssynchronous contraction of the left ventricle is also observed with normal QRSd. We set out to determine how electrical activation of the left ventricular (LV) free wall differed between patients with left bundle-branch block (LBBB) and normal QRS...

متن کامل

Letter by Jackson et al Regarding, "PR Interval Identifies Clinical Response in Patients With Non-Left Bundle Branch Block: A Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy Substudy" by Kutyifa et al.

Letter by Jackson et al Regarding, “PR Interval Identifies Clinical Response in Patients With Non-Left Bundle Branch Block: A Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy Substudy” by Kutyifa et al Kutyifa et al present an interesting post hoc analysis of the Multicenter Automatic Defibrillator Implantation Trial-cardiac resynchronization therapy data...

متن کامل

Integration of mechanical, structural and electrical imaging to understand response to cardiac resynchronization therapy.

INTRODUCTION AND OBJECTIVES There is extensive controversy exists on whether cardiac resynchronization therapy corrects electrical or mechanical asynchrony. The aim of this study was to determine if there is a correlation between electrical and mechanical sequences and if myocardial scar has any relevant impact. METHODS Six patients with normal left ventricular function and 12 patients with l...

متن کامل

Electrical and Mechanical Ventricular Activation During Left Bundle Branch Block and Resynchronization

Cardiac resynchronization therapy (CRT) aims to treat selected heart failure patients suffering from conduction abnormalities with left bundle branch block (LBBB) as the culprit disease. LBBB remained largely underinvestigated until it became apparent that the amount of response to CRT was heterogeneous and that the therapy and underlying pathology were thus incompletely understood. In this rev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2018