Development of calibration techniques for ultrasonic hydrophone probes in the frequency range from 1 to 100 MHz.

نویسندگان

  • S Umchid
  • R Gopinath
  • K Srinivasan
  • P A Lewin
  • A S Daryoush
  • L Bansal
  • M El-Sherif
چکیده

The primary objective of this work was to develop and optimize the calibration techniques for ultrasonic hydrophone probes used in acoustic field measurements up to 100 MHz. A dependable, 100 MHz calibration method was necessary to examine the behavior of a sub-millimeter spatial resolution fiber optic (FO) sensor and assess the need for such a sensor as an alternative tool for high frequency characterization of ultrasound fields. Also, it was of interest to investigate the feasibility of using FO probes in high intensity fields such as those employed in HIFU (high intensity focused ultrasound) applications. In addition to the development and validation of a novel, 100 MHz calibration technique the innovative elements of this research include implementation and testing of a prototype FO sensor with an active diameter of about 10 microm that exhibits uniform sensitivity over the considered frequency range and does not require any spatial averaging corrections up to about 75 MHz. The results of the calibration measurements are presented and it is shown that the optimized calibration technique allows the sensitivity of the hydrophone probes to be determined as a virtually continuous function of frequency and is also well suited to verify the uniformity of the FO sensor frequency response. As anticipated, the overall uncertainty of the calibration was dependent on frequency and determined to be about +/-12% (+/-1 dB) up to 40 MHz, +/-20% (+/-1.5 dB) from 40 to 60 MHz and +/-25% (+/-2dB) from 60 to 100 MHz. The outcome of this research indicates that once fully developed and calibrated, the combined acousto-optic system will constitute a universal reference tool in the wide, 100 MHz bandwidth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A multiple-frequency hydrophone calibration technique.

A method is described for comparing the sensitivity of two hydrophones over the frequency range 1-15 MHz. This technique forms the basis for the dissemination of national ultrasonic standards in the U.K. over this frequency range. A reference hydrophone is placed in an ultrasonic field and then the device being calibrated is substituted and the two output voltages are compared. This substitutio...

متن کامل

A New Method of Ultrasonic Hydrophone Calibration using Wave Propagation Modeling

A new method is presented for hydrophone calibration using the Khokhlov Zabolotskaya Kuznetsov (KZK) equation. Simulated and experimental on-axis finite amplitude distortion time waveforms and frequency spectra are compared. The hydrophone calibration up to 100 MHz is estimated for two different hydrophones.

متن کامل

Phase calibration of hydrophones: heterodyne time-delay spectrometry and broadband pulse technique using an optical reference hydrophone

Two hydrophone calibration techniques are presented which provide amplitude and phase of hydrophone sensitivity. Heterodyne time-delay spectrometry can be applied in the frequency range from 0.5 to 50 MHz to all common hydrophones but needs a standard to obtain absolute values. A pulse technique between 1 and 70 MHz allows exploiting of an optical multilayer hydrophone as a phase standard. In c...

متن کامل

Heterodyne and Time-gated Time-delay Spectrometry for Amplitude and Phase Calibration of Hydrophones

The determination of amplitude and phase of the hydrophone sensitivity using two techniques based on time-delay spectrometry is presented. The frequency range in which the technique can be applied is from 1 MHz to 50 MHz. The agreement with the results obtained by alternative calibration techniques is excellent, which emphasises the correct working of this coherent technique. Introduction Calib...

متن کامل

Nonlinear acoustics determination of phase characteristics of PVDF membrane hydrophones

When an ultrasonic pressure wave propagates through a nonlinear medium, the relative phasing of the generated harmonics causes a distinct asymmetry between the positive and negative pressure levels and between the rise and fall time of examined waveforms. A faithful quantitative reproduction of the source transducer's pressure field requires amplitude and phase measurements by calibrated hydrop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasonics

دوره 49 3  شماره 

صفحات  -

تاریخ انتشار 2009