Goniometric reliability in a clinical setting. Subtalar and ankle joint measurements.

نویسندگان

  • R A Elveru
  • J M Rothstein
  • R L Lamb
چکیده

Measurements of the subtalar joint neutral (STJN) position and passive range of motion (PROM) of the ankle joint and the subtalar joint (STJ) are often part of a physical therapy evaluation. These measurements may be used in treatment planning, such as in the prescription of specialized shoes or orthoses. Therefore, reliability of these measurements, as they are obtained clinically, must be determined. The purpose of this study was to examine the reliability of measurements of the STJN position and of ankle and STJ PROM. To determine reliability, repeated measurements of the STJN position and of STJ PROM were taken on the involved feet of 43 patients with neurologic orthopedic disorders (including both feet of 7 patients), and measurements of ankle PROM (dorsiflexion and plantar flexion) were taken on 42 of these patients (including both feet of 7 patients). Intraclass correlation coefficients (ICCs) for intratester reliability ranged from .74 to .90 for ankle and STJ measurements. The ICCs for intertester reliability were .25 for measuring the STJN position, .32 for STJ inversion, and .17 for SJJ eversion. The ICCs for intertester reliability were .50 for ankle dorsiflexion and .72 for ankle plantar flexion. Goniometric measurements of the STJN position and of PROM of the ankle and STJ appear to be moderately reliable if taken by the same therapist over a short period of time. With the exception of ankle plantar flexion, these measurements cannot be considered to be reliable between therapists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Goniometric reliability in a clinical setting. Elbow and knee measurements.

Reliability of goniometric measurements has been examined only under standardized conditions and usually with healthy subjects. The purpose of this study was to assess goniometric reliability in a clinical setting. The reliability of goniometric measurements of passive elbow and knee positions was assessed using patients as subjects. The effect of using the means of repeated measurements and th...

متن کامل

Systematic Quantification of Stabilizing Effects of Subtalar Joint Soft-Tissue Constraints in a Novel Cadaveric Model.

BACKGROUND Distinguishing between ankle instability and subtalar joint instability is challenging because the contributions of the subtalar joint's soft-tissue constraints are poorly understood. This study quantified the effects on joint stability of systematic sectioning of these constraints followed by application of torsional and drawer loads simulating a manual clinical examination. METHO...

متن کامل

Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting.

The purpose of this study was to examine the intratester and intertester reliability for goniometric measurements of knee flexion and extension passive range of motion (PROM). In addition, parallel-forms reliability for PROM measurements of the knee obtained by use of a goniometer and by visual estimation was examined. The intertester reliability for visual estimates of the PROM of the knee was...

متن کامل

A new device for assessing ankle dorsiflexion motion: reliability and validity.

STUDY DESIGN Clinical measurement. OBJECTIVE To determine the validity and reliability of measures obtained using a custom-made device for assessing ankle dorsiflexion motion and stiffness. BACKGROUND Limited dorsiflexion has been implicated in the evolution of foot pain in a number of clinical populations. Assessment of ankle dorsiflexion range of motion (ROM) is, therefore, commonly perfo...

متن کامل

Tenodeses destroy the kinematic coupling of the ankle joint complex. A three-dimensional in vitro analysis of joint movement.

To study the effect of ligament injuries and surgical repair we investigated the three-dimensional kinematics of the ankle joint complex and the talocrural and the subtalar joints in seven fresh-frozen lower legs before and after sectioning and reconstruction of the ligaments. A foot movement simulator produced controlled torque in one plane of movement while allowing unconstrained movement in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical therapy

دوره 68 5  شماره 

صفحات  -

تاریخ انتشار 1988