Glove tears during arthroscopic shoulder surgery using solid-core suture.

نویسندگان

  • Kevin M Kaplan
  • Konrad I Gruson
  • Chris T Gorczynksi
  • Eric J Strauss
  • Fred J Kummer
  • Andrew S Rokito
چکیده

PURPOSE Surgeons have noticed an increased incidence of finger lacerations associated with arthroscopic knot tying with solid-core suture material. This study examines glove perforations and finger lacerations during arthroscopic shoulder surgery. METHODS We collected 400 surgical gloves from 50 consecutive arthroscopic shoulder repair procedures using No. 2 solid-core sutures. Two surgeons using double gloves were involved in every case, with one being responsible for tying all knots. Powder-free latex gloves were worn in all cases. Knots consisted of a sliding stitch of the surgeon's preference followed by 3 half-hitches via a knot-pusher instrument. All gloves were inspected grossly and then tested for tears with an electroconductivity meter. RESULTS The knot-tying surgeon had significantly more glove tears than the control (P < .01). Tears were localized to the radial side of the index finger of the glove at the distal interphalangeal joint in all cases. Of the tying surgeon's gloves, 68 (34%) were found to have tears. These included 17 inner gloves (17%) and 51 outer gloves (51%). If an inner glove was torn, the corresponding outer glove was torn in all cases. A mean of 3.96 knots were tied in each case. There was a significantly higher incidence of inner glove tears when more than 3 knots were tied (P < .03). There was no significant difference in glove tears between suture types. Finger lacerations did occur in the absence of glove tears. However, in the presence of an inner glove tear, there was a statistically significant association with a finger laceration at the corresponding level (P < .03). CONCLUSIONS Intraoperative glove tears and subsequent finger lacerations occur with a high frequency when arthroscopic knots are tied with solid-core suture material. Risk can potentially be minimized by frequent glove changes or use of more durable, less penetrable gloves. CLINICAL RELEVANCE This study addresses surgeon and patient safety during arthroscopic shoulder surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arthroscopic repair of SLAP lesions with a bioknotless suture anchor.

The diagnosis and treatment of SLAP tears have improved with the development of arthroscopic shoulder surgery techniques. With types 2 and 4 tears, the goal is to restore stability to the labrum and biceps anchor and achieve healing to the glenoid. Suture repair with anchors is currently the repair technique of choice. The purpose of this article is to report a fast and simple method for arthro...

متن کامل

Arthroscopic subscapularis repair using single-row mattress suture technique: clinical results and structural integrity.

BACKGROUND Rupture of the subscapularis (SSC) tendon, isolated or combined, is rare, and the treatment modalities are controversial. The purpose of this study was to evaluate, by magnetic resonance imaging (MRI), the clinical outcomes and structural integrity of the SSC tendon after all-arthroscopic repair with single-row mattress suture for isolated or combined SSC tendon tears. METHODS This...

متن کامل

Knotless Arthroscopic Repair of Subscapularis Tendon Tears Using Looped Suture.

Subscapularis tendon tears present a technical challenge because both diagnosis and arthroscopic treatment can be difficult. One difficulty is the limited visualization and working space of the anterior shoulder. Although most tears of the subscapularis are partial- or full-thickness tears of the upper third of the tendon, occasionally, larger or more retracted tears are encountered. Various te...

متن کامل

Arthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear

BACKGROUND The purpose of our study is to evaluate the clinical results of arthroscopic suture bridge repair for patients with rotator cuff tears. METHODS Between January 2007 and July 2007, fifty-one shoulders underwent arthroscopic suture bridge repair for full thickness rotator cuff tears. The average age at the time of surgery was 57.1 years old, and the mean follow-up period was 15.4 mon...

متن کامل

Surface-holding repair: an original arthroscopic rotator cuff repair technique.

BACKGROUND Arthroscopic rotator cuff repair provides satisfactory results; however, there is still a high rate of re-tear. The objective of this study was to present a surface-holding technique that we recently developed for arthroscopic rotator cuff repair in detail and to evaluate the clinical outcome as well as cuff repair integrity with this new method. MATERIALS AND METHODS A consecutive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 2007