Validation of high temporal resolution spiral phase velocity mapping of temporal patterns of left and right coronary artery blood flow against Doppler guidewire
نویسندگان
چکیده
BACKGROUND Temporal patterns of coronary blood flow velocity can provide important information on disease state and are currently assessed invasively using a Doppler guidewire. A non-invasive alternative would be beneficial as it would allow study of a wider patient population and serial scanning. METHODS A retrospectively-gated breath-hold spiral phase velocity mapping sequence (TR 19 ms) was developed at 3 Tesla. Velocity maps were acquired in 8 proximal right and 15 proximal left coronary arteries of 18 subjects who had previously had a Doppler guidewire study at the time of coronary angiography. Cardiovascular magnetic resonance (CMR) velocity-time curves were processed semi-automatically and compared with corresponding invasive Doppler data. RESULTS When corrected for differences in heart rate between the two studies, CMR mean velocity through the cardiac cycle, peak systolic velocity (PSV) and peak diastolic velocity (PDV) were approximately 40 % of the peak Doppler values with a moderate - good linear relationship between the two techniques (R(2): 0.57, 0.64 and 0.79 respectively). CMR values of PDV/PSV showed a strong linear relationship with Doppler values with a slope close to unity (0.89 and 0.90 for right and left arteries respectively). In individual vessels, plots of CMR velocities at all cardiac phases against corresponding Doppler velocities showed a consistent linear relationship between the two with high R(2) values (mean +/-SD: 0.79 +/-.13). CONCLUSIONS High temporal resolution breath-hold spiral phase velocity mapping underestimates absolute values of coronary flow velocity but allows accurate assessment of the temporal patterns of blood flow.
منابع مشابه
Validation of high temporal resolution spiral phase velocity mapping of coronary artery blood flow against Doppler flow wire
Background The temporal pattern of coronary artery flow velocity through the cardiac cycle provides important information about coronary haemodynamics. The ‘gold standard’ for coronary artery velocity assessment is the Doppler flow wire which is inserted directly into the coronary artery under X-ray fluoroscopic guidance, which is invasive, uses ionising radiation and has a small but significan...
متن کاملInter breath-hold reproducibility of temporal patterns of coronary artery blood flow
Background While blood flow in the majority of arteries peaks in systole, the rhythmic squeezing of the coronary arteries and microcirculation as the heart beats results in left anterior descending artery (LAD) flow being diastolicpredominant while for the right coronary artery (RCA), there is approximately equal flow in systole and diastole. These temporal flow patterns can provide important i...
متن کاملSpiral phase velocity mapping of left and right coronary artery blood flow: correction for through-plane motion using selective fat-only excitation.
PURPOSE To develop a method of correcting both right and left coronary artery flow velocities for the through-plane motion of the vessel, in order to allow details in the temporal flow profiles to be viewed. MATERIALS AND METHODS The methods developed use selective excitation and velocity mapping of the epicardial fat surrounding the artery, either in a separate acquisition (temporal resoluti...
متن کاملComparison of spiral and FLASH phase velocity mapping, with and without breath-holding, for the assessment of left and right coronary artery blood flow velocity.
PURPOSE To develop high temporal resolution coronary artery spiral phase velocity mapping sequences and to compare the results obtained with those from FLASH sequences. MATERIALS AND METHODS Velocity curves were obtained in eight left and eight right coronary arteries using breath-hold interleaved spiral (BH_SP), free-breathing interleaved spiral (FB_SP), breath-hold segmented FLASH (BH_FL), ...
متن کاملThe impact of ischemic heart disease on main pulmonary artery blood flow patterns: a comparison between magnetic resonance phase velocity mapping and transesophageal color Doppler.
OBJECTIVE To give a detailed evaluation on main pulmonary artery blood velocity patterns, in patients with ischemic heart disease and to provide recommendations for pulsed Doppler sample volume placement, in order to optimize cardiac output estimation. METHODS Using magnetic resonance phase and esophageal color Doppler velocity mapping in 12 patients with ischemic heart disease and undergoing...
متن کامل