Measuring the spring constant of atomic force microscope cantilevers: thermal fluctuations and other methods
نویسنده
چکیده
Knowledge of the interaction forces between surfaces gained using an atomic force microscope (AFM) is crucial in a variety of industrial and scientific applications and necessitates a precise knowledge of the cantilever spring constant. Many methods have been devised to experimentally determine the spring constants of AFM cantilevers. The thermal fluctuation method is elegant but requires a theoretical model of the bending modes. For a rectangular cantilever, this model is available (Butt and Jaschke). Detailed thermal fluctuation measurements of a series of AFM cantilever beams have been performed in order to test the validity and accuracy of the recent theoretical models. The spring constant of rectangular cantilevers can also be determined easily with the method of Sader and White. We found very good agreement between the two methods. In the case of the V-shaped cantilever, we have shown that the thermal fluctuation method is a valid and accurate approach to the evaluation of the spring constant. A comparison between this method and those of Sader–Neumeister and of Ducker has been established. In some cases, we found disagreement between these two methods; the effect of non-conservation of material properties over all cantilevers from a single chip is qualitatively invoked. (Some figures in this article are in colour only in the electronic version)
منابع مشابه
Variations in properties of atomic force microscope cantilevers fashioned from the same wafer.
Variations in the mechanical properties of nominally identical V-shaped atomic force microscope (AFM) cantilevers sourced from the same silicon nitride wafer have been quantified by measuring the spring constants, resonant frequencies and quality factors of 101 specimens as received from the manufacturer using the thermal spectrum method of Hutter and Bechhoefer. The addition of thin gold coati...
متن کاملA method for determining the spring constant of cantilevers for atomic force microscopy
Cantilevers fabricated by means of micromachining techniques are usually used for atomic force microscopy. In this paper, the spring constant of an atomic force microscope (AFM) cantilever is determined by using a large-scale cantilever. Since the spring constant of the large-scale cantilever is calibrated accurately, the spring constant of the AFM cantilever is determined precisely by measurin...
متن کاملCalibration of colloid probe cantilevers using the dynamic viscous response of a confined liquid
Articles you may be interested in Adhesive-free colloidal probes for nanoscale force measurements: Production and characterization Rev. Improved in situ spring constant calibration for colloidal probe atomic force microscopy Rev. Accurate noncontact calibration of colloidal probe sensitivities in atomic force microscopy Rev. A calibration method for lateral forces for use with colloidal probe f...
متن کاملAtomic Force Microscope Cantilever Flexural Stiffness Calibration: Toward a Standard Traceable Method
The evolution of the atomic force microscope into a useful tool for measuring mechanical properties of surfaces at the nanoscale has spurred the need for more precise and accurate methods for calibrating the spring constants of test cantilevers. Groups within international standards organizations such as the International Organization for Standardization and the Versailles Project on Advanced M...
متن کاملEffect of cantilever geometry on the optical lever sensitivities and thermal noise method of the atomic force microscope.
Calibration of the optical lever sensitivities of atomic force microscope (AFM) cantilevers is especially important for determining the force in AFM measurements. These sensitivities depend critically on the cantilever mode used and are known to differ for static and dynamic measurements. Here, we calculate the ratio of the dynamic and static sensitivities for several common AFM cantilevers, wh...
متن کامل