Development and validation of an HPLC method to determine the stability of fentanyl citrate and bupivacaine hydrochloride mixtures in infusion solutions
نویسندگان
چکیده
BACKGROUND The use of a combination of different drugs in postoperative analgesia extends the time of analgesia, makes it more efficient and allows the use of lower drug doses, which leads to less risk of side effects and drug dependence. The aim of this study was to develop and validate an HPLC method to determine the stability of fentanyl citrate and bupivacaine hydrochloride mixtures in standard infusion solutions of 0.9% sodium chloride and 5% glucose. METHODS AFTER OPTIMISATION, THE HPLC METHOD PARAMETERS WERE AS FOLLOWS: LiChrospher 100 CN, 250×4 mm (10 µm) column; mobile phase: mixture of acetonitrile and phosphate buffer at pH 2.8 (3:7, V/V) with addition of 0.08 g/l potassium chloride; flow rate: 1.5 ml/min; column temperature: 30°C; spectrophotometric detection at 210 nm. Development of the method involved checking the impact of acetonitrile and KCl concentrations in the mobile phase and choosing the internal standard. Method validation included determining the specificity of the method, its accuracy, linearity, precision, repeatability, limits of detection and quantification. RESULTS The retention times of bupivacaine hydrochloride, fentanyl citrate and procaine hydrochloride, used as an internal standard, were approximately 10 min, 15 min and 5 min, respectively. Method validation confirmed its selectivity, accuracy and precision. The average values of the variation and accuracy coefficients were 0.70% and 99.02% for bupivacaine hydrochloride, and 1.76% and 104.53% for fentanyl citrate. The intermediate precision values were 1.25% for bupivacaine hydrochloride and 1.52% for fentanyl citrate.
منابع مشابه
Comparison of Analgesic Effects of Epidural Infusion of Fentanyl and Fentanyl-bupivacaine in Spine Surgery: A Randomized Clinical Trial Study
Background & Aim: Although most patients experience severe pain after major spinal fixation surgery, little attention has been paid to control it with a multi-modal approach. The aim of this study is to select appropriate method of pain management after spinal surgery. Methods & Materials/Patients: This study was a randomized clinically controlled trial in candidates of spondylolisthesis and...
متن کاملUltrasound Guided Infraclavicular Block for Pain Control After Upper Extremity Surgery
Background: Opioids added to local anesthetics for peripheral nerve blocks may intensify analgesia and prolong analgesic and sensorial block duration. These agents may also cause potentiation and prolongation of motor block. Objective: This study compared the postoperative effects of 30 mL of 0.25% bupivacaine +50 mcg fentanyl and 30 mL of 0.25% bupivaca...
متن کاملDevelopment and validation of an HPLC assay for fentanyl and related substances in fentanyl citrate injection, USP.
The stability indicating properties of the USP method for the assay of fentanyl in fentanyl citrate injection were evaluated [1] by analyzing fentanyl drug substance and product after acid, hydrogen peroxide, heat, and light treatment. N-phenyl-N-(4-piperidinyl)propionamide (PPA), which is a known degradation product/process impurity of fentanyl, was not adequately resolved from the fentanyl pe...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 19 شماره
صفحات -