Bench-Scale Disinfection of Bacteria and Viruses with Pulsed Arc Electrohydraulic Discharge

نویسندگان

  • Lawrence H. Lee
  • Adam J. Arnold
  • Cutberto A. Santillan
  • Monica B. Emelko
  • Sarah E. Dickson
  • Jen-Shih Chang
چکیده

Pulsed arc electrohydraulic discharge (PAED) offers concurrent treatment of chemical and microbial target compounds in water by several mechanisms. Here, Escherichia coli, Bacillus subtilis spore, and MS2 bacteriophage inactivation by PAED were investigated using two bench-scale reactors (0.7 and 3 L). A plasma channel was created between a pair of iron electrodes set 0.5 mm apart in these reactors. Pulsed applied voltage was supplied at approximately 0.3 kJ/pulse (~100 μsec). In the 0.7-L reactor, median E. coli, B. subtilis, and MS2 reductions of 2.4-, 4.6-, and 3.7-log, respectively, were observed after approximately 80 seconds of treatment in water with a conductivity of 14.7 mS; reductions of 2.8-, 4.0-, and 3.7-log, respectively, were observed in treated drinking water fi lter effl uent (conductivity of 610 μS). In the 3-L reactor, at a conductivity of 500 to 600 μS, 1.9and approximately 0.9-log median reductions of E. coli and B. subtilis were achieved after 500 pulses (~3,300 sec); and, at a conductivity of 4.3 mS, median E. coli reductions of 0.5-log were achieved after 50 pulses (400 sec). Further work is necessary to elucidate the primary mechanism(s) of disinfection acting in the PAED system and how they relate to the reactor design, applied power requirements, and disinfection of specifi c target microorganisms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Generation of active entities by the pulsed arc electrohydraulic discharge system and application to removal of atrazine.

Reactions induced by the pulsed arc electrohydraulic discharge (PAED) system in aqueous solutions were studied. PAED was generated by a spark gap type power supply (0.5 kJ/pulse) with rod-to-rod type electrodes in water. The measurements of physical parameters showed that the discharge is characterized by a sudden drop of the voltage while a peak of current occurs. The pressure waveform is comp...

متن کامل

Contaminant Candidate List Viruses: Evaluation of Disinfection Efficacy

BACKGROUND: The current standards for chlorine and monochloramine disinfection of drinking water were established using information obtained from bench-scale disinfection experiments of monodispersed hepatitis A virus. It is not clear whether these standards are sufficient for the four virus types listed on the CCL2. Several disinfection studies have been conducted on representative coxsackievi...

متن کامل

Photocatalytic inactivation of viruses using titanium dioxide nanoparticles and low-pressure UV light.

The carcinogenic potential of chlorine disinfection by-products and recent changes in water quality regulations have led to a greater emphasis on alternative disinfection mechanisms. In this study, the efficacy of bench-scale and pilot-scale titanium dioxide (TiO(2)) photocatalytic disinfection was explored using four bacteriophages (MS2, PRD1, phi-X174, and fr). The optimized bench-scale exper...

متن کامل

Electrohydraulic shock wave generation as a means to increase intrinsic permeability of mortar

This article discusses the influence of compressive shock waves on the permeability of cementitious materials. Shock waves are generated in water by Pulsed Arc Electrohydraulic Discharges (PAED). The practical aim is to increase the intrinsic permeability of the specimens. The maximum pressure amplitude of the shock wave is 250 MPa. It generates damage in the specimens and the evolution of dama...

متن کامل

Scale Effects on the Discharge Coefficient of Ogee Spillway with an Arc in Plan and Converging Training Walls

Dam spillways are the structures that lead rightly and safely the outflow downstream, so that the dam integrity can be guaranteed. Many accidents with dams have been caused by an inadequate spillway design or insufficient capacity. To accurately respond the hydraulic spillways, designers use physical modeling for designing this kind of structures. The scale effect in the spillway modeling, as a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008