Frequency of Seeing Functions for Intensity Discrimination at Various Levels of Adapting Intensity
نویسنده
چکیده
1. The percentage of times a human subject detects an increment (DeltaI) in intensity was determined as a function of the magnitude of the increment and the magnitude of the stimulus (I) to which the increment is added. 2. Foveal stimulation was used, and five frequency of seeing curves were obtained at each of nine values of adapting intensity covering the range from -1.45 to 4.45 log photons. Each frequency of seeing curve shows the percentage of times an increment in intensity is detected as a function of the logarithm of the increment. 3. The slope of the frequency of seeing curve increases slightly with an increase in I and finally becomes independent of I at medium to high intensities. 4. The implications of the results for quantum theories of visual excitation are considered.
منابع مشابه
سایکوآکوستیک و درک گفتار در افراد مبتلا به نوروپاتی شنوایی و افراد طبیعی
Background: The main result of hearing impairment is reduction of speech perception. Patient with auditory neuropathy can hear but they can not understand. Their difficulties have been traced to timing related deficits, revealing the importance of the neural encoding of timing cues for understanding speech. Objective: In the present study psychoacoustic perception (minimal noticeable differen...
متن کاملPrecipitation Intensity-Duration-Frequency Functions for the Bannu Region NWFP Pakistan (RESEARCH NOTE)
The function of precipitation intensity-duration-frequency is needed for the planning and design of water resource projects. Short duration precipitation data are hardly available. However the total hourly-recorded available precipitation data for different parts of NWFP from different departments have been collected and analyzed for the present study. The data from WAPDA is found to be more au...
متن کاملNumerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملFrequency discrimination at 1200 Hz in the presence of high-frequency masking noise.
To evaluate the possible contribution of high-frequency hearing to frequency discrimination at lower frequencies, pure-tone frequency discrimination tasks at 1200 Hz, with and without high-frequency masking noise, were performed by two highly practiced normal-hearing listeners. Signal levels ranged from 10 to 80 dB SPL. Spectra of the three high-frequency masking noises ranged from 1.8 to 2.1 k...
متن کاملDerivation of Intensity -Duration-Frequency -Area(IDFA) Curves for Mashhad City
A knowledge of rainfall distribution over a finite area is needed for small bydraulic structures design. Hydrologists have always been concerned about Depth- Area- Duration (DAD) for a specific storm in a watershed. An intense storm occurred on June 6, 1992 which claimed some lives in parts of Mashhad, Khorasan Province, Iran. Data of rainfall depth at 29 raingauge stations around the city and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of General Physiology
دوره 34 شماره
صفحات -
تاریخ انتشار 1951