Estimated Preejection Period (pep) Based on The

نویسندگان

  • René van Lien
  • Nienke Schutte
  • Jan H. Meijer
چکیده

detection of the R-wave and dZ/dt-min peaks does not adequately reflect the actual PEP across a wide range of laboratory and ambulatory conditions. Abstract The current study evaluates the validity of the PEP computed from a fixed value for the Q-wave onset to R-wave peak (QR) interval and an R-wave peak to B-point (RB) interval that is estimated from the R-peak to dZ/dt-min peak (ISTI) interval. Ninety-one participants participated in a 90 minute laboratory experiment in which a variety of often employed physical and mental stressors were presented and 31 further participants participated in a structured 2 hour ambulatory recording in which they partook in natural activities that induced large variation in posture and physical activity. PEP, QR interval, and ISTI were scored and rigorously checked by interactive inspection. Across the very diverse laboratory and ambulatory conditions the QR interval could be approximated by a fixed interval of 40 ms but 95% confidence intervals were large (25.5 to 54.5 ms). Multilevel analysis showed that 79% to 81% of the within and between-participant variation in the RB interval could be predicted by the ISTI with a simple linear regression equation. However, the optimal intercept and slope values in this equation varied significantly across participants and study setting. Bland Altman plots revealed a large discrepancy between the estimated PEP using the R-wave peak and dZ/dt-min peak and the actual PEP based on the Q-wave onset and B-point. We conclude that the PEP estimated from a fixed QR interval and the ISTI could be a useful addition to the psychophysiologist's toolbox, but that it cannot replace the actual PEP to index cardiac sympathetic control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimated preejection period (PEP) based on the detection of the R-wave and dZ/dt-min peaks

The validity of estimating the PEP from a fixed value for the Q-wave onset to the Rwave peak (QR) interval and from the R-wave peak to the dZ/dt-min peak (ISTI) interval is evaluated. Ninety-one subjects participated in a laboratory experiment in which a variety of physical and mental stressors were presented and 31 further subjects participated in a sequence of structured ambulatory activities...

متن کامل

Innovative Methodology The respiratory change in preejection period: a new method to predict fluid responsiveness

Bendjelid, Karim, Peter M. Suter, and Jacques A. Romand. The respiratory change in preejection period: a new method to predict fluid responsiveness. J Appl Physiol 96: 337–342, 2004; 10.1152/ japplphysiol.00435.2003.—The accuracy and clinical utility of preload indexes as bedside indicators of fluid responsiveness in patients after cardiac surgery is controversial. This study evaluates whether ...

متن کامل

Comparison of within and between subject variation in salivary alpha-amylase and the preejection period

This chapter wil be merged with chapter 5 and submitted to PNEC. Abstract Recently, the secretion of the salivary enzyme alpha-amylase (sAA) has gained interest as a potential non-invasive biomarker for activity of the sympathetic nervous system (SNS). In this study we compared sAA to an established measure of SNS activity, the preejection period (PEP). Twenty-three students between 18 and 35 y...

متن کامل

Estimated preejection period (PEP) based on the detection of the R-wave and dZ/dt-min peaks does not adequately reflect the actual PEP across a wide range of laboratory and ambulatory conditions.

The current study evaluates the validity of the PEP computed from a fixed value for the Q-wave onset to R-wave peak (QR) interval and an R-wave peak to B-point (RB) interval that is estimated from the R-peak to dZ/dt-min peak (ISTI) interval. Ninety-one subjects participated in a 90min laboratory experiment in which a variety of often employed physical and mental stressors were presented and 31...

متن کامل

Comparing low frequency heart rate variability and preejection period: two sides of a different coin.

It has been hypothesized that the ratio of heart rate variability in the low- (LF) and high- (HF) frequency bands may capture variation in cardiac sympathetic control. Here we tested the temporal stability of the LF/HF ratio in 24-h ambulatory recordings and compared this ratio to the preejection period (PEP), an established measure of cardiac sympathetic control. Good temporal stability was fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013