Accuracy and concurrent validity of a sensor-based analysis of sit-to-stand movements in older adults.

نویسندگان

  • G Ruben H Regterschot
  • Wei Zhang
  • Heribert Baldus
  • Martin Stevens
  • Wiebren Zijlstra
چکیده

Body-fixed motion sensors have been applied for the assessment of sit-to-stand (STS) performance. However, the accuracy and concurrent validity of sensor-based estimations of the body's center of mass (CoM) motion during STS are unclear. Therefore, this study investigated the accuracy and concurrent validity of sensor-based measures of CoM motion during STS in older adults. Accuracy and concurrent validity were investigated by comparing the sensor-based method to a force plate method. Twenty-seven older adults (20 females, 7 males; age: 72-94 years) performed five STS movements while data were collected with force plates and motion sensors on the hip and chest. Hip maximal acceleration provided an accurate estimation of the center of mass (CoM) maximal acceleration (limits of agreement (LOA) smaller than 5% of the CoM maximal acceleration; estimated and real CoM maximal acceleration did not differ (p=0.823)). Other hip STS measures and the chest STS measures did not provide accurate estimations of CoM motion (LOA ranged from -155.6% to 333.3% of the CoM value; sensor-based measures overestimated CoM motion (range p: <0.001 to 0.01)). However, the hip sensor did not overestimate maximal jerk of the CoM (p=0.679). Moderate to very strong associations were observed between sensor-based estimations and actual CoM motion (range r=0.64-0.94, p<0.001). Hence, sensor-based estimations of CoM motion during STS are possible, but accuracy is limited. The sensor-based method cannot replace laboratory methods for a mechanical analysis of CoM motion during STS but it may be a practical alternative for the clinical assessment of STS performance in older persons.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated approach for quantifying the repeated sit-to-stand using one body fixed sensor in young and older adults.

Much is known about the sit-to-stand (STS) and its biomechanics. Currently, however, there is little opportunity for instrumented quantification of the STS as part of screening or diagnosis in clinical practice. The objectives of the present study were to describe the feasibility of using an automated approach for quantifying the STS using one sensor location and to start testing the discrimina...

متن کامل

Validation of seat-off and seat-on in repeated sit-to-stand movements using a single-body-fixed sensor.

The identification of chair rise phases is a prerequisite for quantifying sit-to-stand movements. The aim of this study is to validate seat-off and seat-on detection using a single-body-fixed sensor against detection based on chair switches. A single sensor system with three accelerometers and three gyroscopes was fixed around the waist. Synchronized on-off switches were placed under the chair....

متن کامل

Effect of Handrail Height on Sit-To-Stand Movement

BACKGROUND Care-needing older adults and disabled individuals often require handrails for assistance of movements, such as sit-to-stand movements. Handrails must be set at the appropriate position; however, the effects of handrail height on joint movement and center-of-gravity movements during sit-to-stand movement remain unclear. In the present study, we sought to clarify the effects of handra...

متن کامل

The Relationship Between Demographic, Health, Physical Fitness and Socioeconomic Determinants and Functional Performance of Elderly People

Purpose: Increased life expectancy leads to an increase in the elderly population. However, with an increase in the age, the number of chronic diseases and cognitive disorders also increases. Since the social, cultural, environmental, lifestyle and health-related behavior is specific to each nation, the present study aimed at investigating the relationship between socio-economic status, health,...

متن کامل

Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.

This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Gait & posture

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2016