Radiation dose survey in a paediatric cardiac catheterisation laboratory equipped with flat-panel detectors.

نویسندگان

  • O Dragusin
  • M Gewillig
  • W Desmet
  • K Smans
  • L Struelens
  • H Bosmans
چکیده

Flat-panel X-ray detectors for fluoroscopy represent a modern imaging equipment that is being implemented in paediatric cardiac catheterisation laboratories. Infants and children represent a group of patients with a high radiosensitivity. A survey of 273 (126 diagnostic and 147 therapeutic) paediatric catheterisations was performed to investigate the radiation doses delivered by the new X-ray system. Statistical parameters (75th, 50th and 25th percentiles) of dose-area product (DAP) and fluoroscopy time are reported for patients divided into six age groups: 0-30 d, >1-12 m, >1-3, >3-5, >5-10 and >10-15 y. For accurate risk estimation, effective dose (E) has been determined for all patients using the PCXMC software. For diagnostic procedures, the third quartile of E ranges from 11.3 mSv for newborns to 7 mSv for children of 10-15 y. Therapeutic procedures are more complex than diagnostic. Consequently, the third quartile of E is 22.6 mSv (0-30 d), 18.6 (>1-12 m), 13.3 (>1-3 y), 21.5 (>3-5 y), 17.8 (>5-10 y) and 34.1 mSv (>10-15 y). Dose conversion factors, which relate the DAP and E, have been estimated for each age group. The results of this study may serve as a first step in the optimisation process, in order to make full use of the dose reduction potential of flat-panel systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flat detector versus image intensifier in cardiology. Why are patient doses initially higher?

Our purpose in this paper is to study the differences in patient doses imparted using dynamic flat detectors (FD) as opposed to using image intensifier (II) technology for interventional cardiology within two different European Centres, and then analyse the reasons for such differences. Several x-ray systems from two different manufacturers equipped with FDs ands IIs were used over the last 4 y...

متن کامل

Comparative Study on the Radiation Damage of a-Si : H p-i-n Diodes Made by PECVD and Ion Shower Doping

Flat-panel detectors using amorphous silicon p-i-n diodes have been developed for chest and therapeutic portal imaging. In radiation therapy, an imaging device is exposed to a high radiation dose. The radiation damage affects the leakage current of diode and may decrease the whole system performance. In this research, we have investigated the radiation damage to the leakage current of a-Si : H ...

متن کامل

Radiation exposure to anaesthetists during interventional radiology.

This prospective study determined the level of radiation exposure of anaesthetists during interventional radiological procedures performed in the endoscopic retrograde cholangiopancreatography suite and cardiac catheterisation laboratory and compared it with the current safety guidelines. Anaesthetists wore area-specific lithium fluoride thermo-luminescent dosimeter badges at standardised posit...

متن کامل

In vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)

Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...

متن کامل

SCAI consensus document on occupational radiation exposure to the pregnant cardiologist and technical personnel.

Concerns regarding radiation exposure and its effects during pregnancy are often quoted as an important barrier preventing many women from pursuing a career in Interventional Cardiology. Finding the true risk of radiation exposure from performing cardiac catheterisation procedures can be challenging and guidelines for pregnancy exposure have been inadequate. The Women in Innovations group of Ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 129 1-3  شماره 

صفحات  -

تاریخ انتشار 2008