Lower limb pneumatic compression during dobutamine stress echocardiography in patients with normal resting wall motion: will it increase diagnostic accuracy?

نویسندگان

  • Zainab Abdel-Salam
  • Lawra Allam
  • Bassem Wadie
  • Bassem Enany
  • Wail Nammas
چکیده

BACKGROUND Pneumatic compression of the lower part of the body increases systemic vascular resistance and left ventricular afterload. AIM We compared the diagnostic accuracy of dobutamine stress echocardiography (DSE) with pneumatic compression of the lower extremities, vs. standard DSE, for detection of angiographically significant coronary artery disease (CAD) in patients with normal baseline resting wall motion. METHODS We enrolled 70 consecutive patients with no resting wall motion abnormalities (WMA), who underwent DSE. DSE was repeated with pneumatic compression of the lower extremities three days after the initial standard DSE. A positive test was defined as the induction of WMA in at least two contiguous non-overlap segments at any stage of dobutamine infusion. Significant coronary stenosis was defined as ≥ 50% obstruction of ≥ 1 sizable artery by coronary angiography. RESULTS The mean age of the study cohort was 54.7 ± 9.9 years; 55.7% were females. Thirty-eight (54.3%) patients had significant CAD. The mean test duration was 15.8 ± 5.1 min for standard DSE and 11.7 ± 4.1 min for DSE with pneumatic compression. Analysis of standard DSE revealed sensitivity, specificity, and positive and negative predictive values of 81.6%, 90.6%, 91.2%, and 80.6%, respectively; overall accuracy was 85.7%. Analysis of DSE with pneumatic compression revealed sensitivity, specificity, and positive and negative predictive values of 89.5%, 87.5%, 89.5%, and 87.5%, respectively; overall accuracy was 88.6%. CONCLUSIONS In symptomatic patients with suspected CAD referred for evaluation by DSE, who have no resting wall motion abnormalities, pneumatic compression of the lower extremities during DSE improved the sensitivity but slightly reduced the specificity for detection of angiographically significant CAD, compared with standard DSE. Moreover, it reduced the test duration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pneumatic lower extremity compression during dobutamine stress echocardiography.

BACKGROUND Afterload is expected to increase with pneumatic compression of the lower extremities. There are left ventricular (LV) wall stress, which is the most important factor determining myocardial oxygen demand, will also increase, leading to an increase in the sensitivity of dobutamine stress echocardiography (DSE) or a shortened time to a positive response. METHODS AND RESULTS In 40 pat...

متن کامل

Accuracy of dobutamine stress echocardiography in detecting coronary artery disease.

The diagnostic accuracy of dobutamine stress echocardiography (DSE) (incremental infused doses of 5, 10, 20 and 30 micrograms/kg/min) was evaluated in 141 patients who underwent coronary arteriography within 2 weeks of DSE. All patients were being evaluated for known or suspected coronary artery disease (CAD). DSE was interpreted blindly as normal or showing evidence of CAD, depending on the pr...

متن کامل

Systolic left ventricular long axis function during dobutamine stress echocardiography.

AIMS To compare long-axis function and wall motion analysis for the detection of significant coronary artery stenoses in patients with single and multivessel disease. METHODS AND RESULTS We performed dobutamine stress echocardiography in 67 subjects, 14 with normal coronary anatomy, and 53 with significant coronary disease. A blunted increase in mean long-axis shortening of <0.25 cm was the b...

متن کامل

Influence of wall stress and left ventricular geometry on the accuracy of dobutamine stress echocardiography.

OBJECTIVE The goal of this study was to determine whether wall stress at rest and during stress could explain the influence of left ventricular (LV) morphology on the accuracy of dobutamine stress echocardiography (DSE). BACKGROUND The sensitivity of DSE appears to be reduced in patients with concentric remodeling, but the cause of this finding is unclear. METHODS We studied 161 patients wi...

متن کامل

Myocardial performance after transmyocardial revascularization with CO(2)laser. A dobutamine stress echocardiographic study.

AIMS Transmyocardial laser revascularization is a treatment for patients with severe angina pectoris not eligible for conventional revascularization. The effects on myocardial function and reversible ischaemia have not been clarified. METHODS AND RESULTS One hundred patients with refractory angina not eligible for conventional revascularization were randomized 1:1 to receive continued optimal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Kardiologia polska

دوره 73 8  شماره 

صفحات  -

تاریخ انتشار 2015