Comparison of intensity‐modulated radiotherapy and forward‐planning dynamic arc therapy techniques for prostate cancer

نویسندگان

  • Mohamed Metwaly
  • Awaad Mousa Awaad
  • El‐Sayed Mahmoud El‐Sayed
  • Abdel Sattar Mohamed Sallam
چکیده

We compare an inverse-planning intensity-modulated radiotherapy (IMRT) technique with three previously published forward-planning dynamic arc therapy techniques and a newly implemented technique for treatment of prostate only. The three previously published dynamic arc techniques are dynamic arc therapy (DAT), two-axis dynamic arc therapy (2A-DAT), and modified dynamic arc therapy (M-DAT). The newly implemented technique is the bilateral wedged dynamic arc (BW-DAT). In all dynamic arcs, the multileaf collimator is moving during rotation to fit the prostate, except that, in 2A-DAT, it is fitting two separate symmetrical rhombi including the prostate. The rectum is shielded during rotation only in the cases of M-DAT and BW-DAT. The results obtained indicate that the BW-DAT, M-DAT, and DAT techniques provide the intended dose coverage of the prescribed dose to the planning target volume (PTV)--that is, 95% of the PTV is covered by 100% of the dose. The maximum dose to a 3-cm margin of healthy tissue that surrounds the PTV is lower by 2.5% in the case of IMRT than in both BW-DAT and M-DAT, but it is lower by 5.0% than that in both DAT and 2A-DAT. The maximum dose to the rest of the healthy tissue in the case of BW-DAT is 33.2 Gy +/- 2.2 Gy. This dose covers percentage healthy body volumes of 8% +/- 3.2% with IMRT, 4% +/- 1.5% with DAT, and 6% +/- 1.2% with both 2A-DAT and M-DAT. Also, this dose is much lower than the accepted maximum dose (52 Gy) to the femoral heads and necks according to Report 62 from the International Commission on Radiation Units and Measurements. Accordingly, it would be possible to neglect delineation of the femoral heads and necks as organs at risk in cases of BW-DAT. Doses to 15%, 25%, 35%, and 50% (D15%, D25%, D35%, and D50%) of the rectum volume in the case of BW-DAT were 43.5 Gy +/- 8.6 Gy, 24.2 Gy +/- 8.7 Gy, 13.2 Gy +/- 4.2 Gy, and 5.7 Gy +/- 2.1 Gy respectively. The D15% of rectum in the case of IMRT was lower than that in BW-DAT, M-DAT, 2A-DAT, and DAT by 7.3%, 10.3%, 33.0%, and 17.6% of the prescribed dose (78 Gy in 39 fractions) respectively. The D25%, D35%, and D50% of the rectum volume in the cases of IMRT and DAT were comparable (with a maximum variation of 4.5%); they were similarly comparable in the cases of M-DAT and BW-DAT (with maximum variation of 1.5%). These same doses in BW-DAT were lower than those in IMRT by 8.7%, 10.6%, and 6.2% respectively, but they were quite lower than those in 2A-DAT, because the average variation was 41.6% (with a maximum of 44.0%). The D15%, D25%, D35%, and D50% of the bladder volume in the case of BW-DAT were 33.2 Gy +/- 10.9 Gy, 17.4 Gy +/- 7.9 Gy, 6.5 Gy +/- 4.3 Gy, and 4.2 Gy +/- 3.5 Gy respectively. The D15% and D25% of the bladder in the cases of IMRT, M-DAT, and BW-DAT were comparable (with a maximum variation of 2.2% and 3.6% respectively), and the mean values of each dose were lower in DAT by 14.3% and 11.7% respectively. However, the values of D35% and D50% in the four techniques were comparable, with maximum variations of 5.1% and 2.7% respectively. The D15%, D25%, D35%, and D50% of the bladder in the case of DAT were lower than those in 2A-DAT by 20.1%, 26.9%, 16.0%, and 2.7% respectively. Ion chamber measurements showed good agreement between the calculated and measured isocentric doses (maximum deviation: 3.2%). Accuracy of the dose distribution calculation for BW-DAT was evaluated by film dosimetry using a gamma index, allowing 3% dose variation and 3 mm distance to agreement as the individual acceptance criteria. We found that fewer than 6.5% of the pixels in the dose distributions of the scanned and calculated area of 10 x 10 cm failed the acceptance criteria. We conclude that, in addition to simplicity of the dose calculation, the BW-DAT technique provides the intended concave dose distribution for treatment of the prostate only. Compared with IMRT, it produces better dose protection to the most of the rectum volume and to the healthy tissue outside the treatment volume. Also, as compared with the other forward planning dynamic arc techniques, it gives the most favorable isodose distributions to the prostate and rectum.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

Optimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective

Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives.  Material...

متن کامل

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

Dosimetric Comparison and Evaluation of 4 Stereotactic Body Radiotherapy Techniques for the Treatment of Prostate Cancer

PURPOSE The aim of this study was to compare dosimetric characteristics, monitor unit, and delivery efficiency of 4 different stereotactic body radiotherapy techniques for the treatment of prostate cancer. METHODS This study included 8 patients with localized prostate cancer. Dosimetric assets of 4 delivery techniques for stereotactic body radiotherapy were evaluated: robotic CyberKnife, nonc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2008