Comparison of six phantoms for entrance skin dose evaluation in 11 standard X‐ray examinations
نویسندگان
چکیده
Entrance skin dose (ESD) is an important parameter for assessing the dose received by a patient in a single radiographic exposure. The most useful way to evaluate ESD is either by direct measurement on phantoms using an ionization chamber or using calculations based on a mathematical model. We compared six phantoms (three anthropomorphic, two physical, and one mathematical) in 11 standard clinical examinations (anterior-posterior (AP) abdomen, posterior-anterior (PA) chest, AP chest, lateral (LAT) chest, AP lumbar spine, LAT lumbar spine, LAT lumbo-sacral joint, AP pelvis, PA skull, LAT skull, and AP urinary tract) for two reasons: to determine the conversion factors to use for ESDs measured on different phantoms and to validate the mathematical model used. First, a comparison was done between the three anthropomorphic phantoms (Alderson Rando, chest RSD-77SPL, and 3M skull) and the two physical phantoms (Uniform and AAPM 31); for each examination we obtained "relative entrance skin dose factors." Second, we compared these five phantoms with the mathematical phantom: the overall accuracy of the model was better than 14%. Total mathematical model and total ionization chamber uncertainties, calculated by quadratic propagation of errors of the single components, were estimated to be on the order of +/-12% and +/-3%, respectively. To reduce the most significant source of uncertainty, the overall accuracy of the model was recalculated using new backscatter factors. The overall accuracy of the model improved: better than 12%. For each examination an anthropomorphic phantom was considered as the gold standard relative to the physical phantoms. In this way, it was possible to analyze the variations in phantom design and characteristics. Finally, the mathematical model was validated by more than 400 measurements taken on different phantoms and using a variety of radiological equipment. We conclude that the mathematical model can be used satisfactorily in ESD evaluations because it optimizes available resources, it is based on direct measurements, and it is an easy dynamic tool.
منابع مشابه
Assessment of Patients’ Entrance Skin Dose from Diagnostic X-ray Examinations at Public Hospitals of Akwa Ibom State, Nigeria
Introduction High doses of ionizing radiation can lead to adverse health outcomes such as cancer induction in humans. Although the consequences are less evident at very low radiation doses, the associated risks are of societal importance. This study aimed at assessing entrance skin doses (ESDs) in patients undergoing selected diagnostic X-ray examinations at public hospitals of Akwa Ibom State,...
متن کاملDoses Received by Patients during Thorax X-Ray Examinations
Introduction Radiation exposures from diagnostic medical examinations are generally low and are almost always justified by the benefits of accurate diagnosis of possible disease conditions. Therefore, entrance skin dose (ESD), body organ dose (BOD), and effective dose (ED) from adult patients undergoing routine thorax posterior-anterior (PA) and thorax right lateral (RLAT) were estimated in Uni...
متن کاملEntrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals
Background: There is not any report on the radiation doses received by patients in diagnostic radiology sections in hospitals under control of Chaharmahal and Bakhtiari Medical Sciences University, in the south west of Iran. Objectives: The aim of this study is measurement of entrance surface doses (ESD) for the most routine types of X-ray procedures in radiology centers as part of ongoing d...
متن کاملPatient dose in routine X-ray examinations in Yazd state
Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...
متن کاملLocal Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran
Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...
متن کامل