The Spatial Resolution of Silicon-Based Electron Detectors in β- Autoradiography

نویسندگان

  • Jorge Cabello
  • Kevin Wells
چکیده

Thin tissue autoradiography is an imaging modality where ex-vivo tissue sections are placed in direct contact with autoradiographic film. These tissue sections contain a radiolabelled ligand bound to a specific biomolecule under study. This radioligand emits βor β+ particles ionising silver halide crystals in the film. High spatial resolution autoradiograms are obtained using low energy radioisotopes, such as 3H where an intrinsic 0.1-1 μm spatial resolution can be achieved. Several digital alternatives have been presented over the past years to replace conventional film but their spatial resolution has yet to equal film, although silicon-based imaging technologies have demonstrated higher sensitivity compared to conventional film. It will be shown in this work how pixel size is a critical parameter for achieving high spatial resolution for low energy uncollimated beta imaging. In this work we also examine the confounding factors impeding silicon-based technologies with respect to spatial resolution. The study considers charge diffusion in silicon and detector noise, and this is applied to a range of radioisotopes typically used in autoradiography. Finally an optimal detector geometry to obtain the best possible spatial resolution for a specific technology and a specific radioisotope is suggested.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A "Bioscope" system using double-sided silicon strip detectors and self-triggering read-out chips

The components and the design of a 640 by 640 channel radiation detection system based on double-sided silicon strip detectors and self-triggering read-out chips are presented. The system has been designed for applications in autoradiography and X-ray imaging in medicine, biology and other fields. Images and results from first tests of the system are shown.

متن کامل

A Dual Threshold Method to Independently Control Spatial Resolution and Sensitivity in β Imaging

A wide variety of digital alternatives have been presented to replace traditional film emulsion as detection medium in βAutoradiography. The main claim of most of the alternatives is higher sensitivity. On the other hand, spatial resolution remains the main problem to solve to be able to offer a sensible alternative to film. Solid state detectors, mainly made of silicon, are being used very act...

متن کامل

High spatial resolution energy dispersive X-ray spectrometry in the SEM and the detection of light elements including lithium

Current technology for energy-dispersive X-ray spectrometry using silicon-drift detectors in combination with the latest field-emission scanning electron microscopes delivers routine nanoscale characterisation of structures as small as 50 nm. This performance relies on a combination of high spectral resolution and large sensor area. Results from the latest developments in low-noise electronics ...

متن کامل

Fabrication and characterization of monolithically integrated microchannel plates based on amorphous silicon

Microchannel plates are vacuum-based electron multipliers for particle--in particular, photon--detection, with applications ranging from image intensifiers to single-photon detectors. Their key strengths are large signal amplification, large active area, micrometric spatial resolution and picosecond temporal resolution. Here, we present the first microchannel plate made of hydrogenated amorphou...

متن کامل

Comparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010