چکیده

To the Editor: The recent paper by Eder et al. (1) recalls, among other things, the problems that a clinical STAT laboratory has to face in the case of ethylene glycol poisoning. As an alternative to the precise and accurate gas chromatographic technique, the enzymatic assay with glycerol dehydrogenase (EC 1.1.1.6) and NADH as tracer has been proposed by various authors [see, e.g., (2–4)]. The relative nonspecificity of glycerol dehydrogenase from Enterobacter aerogenes toward diols and triols allows interference with this test by propylene glycol, glycerol, 1,2-butanediol, and 2,3-butanediol (2, 5, 6). Nonetheless, its usefulness in emergency screening for ethylene glycol has been stressed, particularly for its technical simplicity (2). Rynder et al. (2) used an analyzer, the Du Pont aca SX (presently distributed by Dade Behring Inc., Deerfield, IL), that is particularly suited for emergency situations. Presently this instrument, together with the more recent version, the aca STAR, is still widely used in laboratories both in this country and in the United States. Unfortunately, the product that, following the method of Rynder et al., we were using to avoid interference from endogenous triacylglycerols and glycerol (triglyceride test kit for Monarch, cat. no. 35190, Instrumentation Laboratory) is no longer available in our country. Because skilled personnel are not available at all times in our emergency laboratory and because cases of ethylene glycol poisoning are infrequent but not uncommon, I decided to continue to use the aca method whenever the gas chromatographic technique was not available. The modification I make is trivial: I cut compartment no. 2 (ingredients: lipase and stabilizers) of the aca triglyceride analytical test pack (Du Pont, cat. no. 702230901), wash it with deionized water, and firmly reseal the hole with transparent adhesive tape. I calibrate the test with a 16 mmol/L solution of ethylene glycol in pooled sera that are free of ethylene glycol, as assessed by gas chromatographic analysis, and use the same pooled sera as a blank. Linearity was studied by serial dilutions of the calibrator in ethylene glycol-free pooled sera down to the concentration of 1.6 mmol/L. The linear regression analysis of the results gave the following statistics: dose 5 0.955 3 response 2 0.04 mmol/L, n 5 10, r 5 0.995, Syux 5 0.41 mmol/L. The test is recalibrated every month. In our laboratory, we are aware that the results obtained in this way need cautious interpretation and gas chromatographic confirmation; however, this test permits us to screen economically for ethylene glycol with a typical turnaround time ,30 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Emergency screening for ethylene glycol in serum.

We have exploited the "interference" of ethylene glycol in the Du Pont aca triglyceride method to develop a convenient and rapid screening method for detecting ethylene glycol in serum. Pretreatment of patient's serum with lipase, glycerol kinase, and other cofactors usually added for triglyceride analysis removes triglycerides and glycerol, but not ethylene glycol, from the sample. The aca tri...

متن کامل

Developmental toxicity and structure/activity correlates of glycols and glycol ethers.

In recent years, the National Toxicology Program (NTP) has selected numerous glycol ethers for testing in routine laboratory mammals to ascertain the magnitude of their ability to injure the conceptus. From the lists available of ongoing and projected NTP test chemicals, a series of glycol ethers was selected for examination in vitro in the hydra assay. Also tested were additional chemicals of ...

متن کامل

Rapid and specific quantification of ethylene glycol levels: adaptation of a commercial enzymatic assay to automated chemistry analyzers.

Ethylene glycol ingestion, accidental or intentional, can be a life-threatening emergency. Assays are not available from most clinical laboratories, and, thus, results often require many hours or days to obtain. Enzymatic assays, adaptable to automated chemistry analyzers, have been evaluated, but they have been plagued by analytic problems. With an alternative method of data analysis applied t...

متن کامل

Developing of Ethylene Glycol as a New Reducing Agent for Preparation of Pd-Ag/PSS Composite Membrane for Hydrogen Separation

In the present work, for the first time, a palladium-silver membrane has been prepared by electroless plating on the surface of a porous stainless steel disk by using ethylene glycol as a new reducing agent and polyol process. The reducing action of ethylene-glycol in the presence of PVP as a protecting surface agent produces a membrane with finely divided powder and nano-sized pores. Furthermo...

متن کامل

Evaluation of 60 chemicals in a preliminary developmental toxicity test.

The number of chemicals in commerce which have not been evaluated for potential developmental toxicity is large. Because of the time and expense required by conventional developmental toxicity tests, an abbreviated assay is needed that will preliminarily evaluate otherwise untested chemicals to help prioritize them for conventional testing. A proposed short-term in vivo assay has been used in a...