Assessment of choroidal thickness and volume during the water drinking test by swept-source optical coherence tomography.

نویسندگان

  • Kaweh Mansouri
  • Felipe A Medeiros
  • Nicholas Marchase
  • Andrew J Tatham
  • Daniel Auerbach
  • Robert N Weinreb
چکیده

OBJECTIVE To evaluate changes in peripapillary and macular choroidal thickness and volume after the water-drinking test (WDT) using swept-source optical coherence tomography (SS OCT). DESIGN Prospective, cross-sectional, observational study. PARTICIPANTS Fifty-six eyes of 28 healthy volunteers. METHODS Participants underwent a 3-dimensional optic disc and macula scanning protocol with a prototype SS OCT (Topcon, Inc., Tokyo, Japan) at baseline and 15, 30, 45, and 120 minutes after the start of the WDT. The WDT consisted of drinking 1000 ml of water within 5 minutes. Objective measurements of the choroid were obtained with automated segmentation of the choroidal boundaries. MAIN OUTCOME MEASURES Choroidal thickness and volume. RESULTS Mean age ± standard deviation of participants was 35.6 ± 9.1 years. Intraocular pressure (IOP) increased from 14.9 ± 2.7 mmHg at baseline to a peak of 16.8 ± 3.0 mmHg 15 minutes after the WDT (P < 0.001). Mean baseline choroidal thickness and volume were 181.3 ± 50.8 μm and 6.19 ± 1.80 mm(3), respectively, at the optic disc and 217.4 ± 43.6 μm and 7.83 ± 1.55 mm(3), respectively, at the macula. After the WDT, peripapillary and macular choroidal thickness increased by a maximum of 5.7% (P<0.001) and 4.3% (P<0.001), respectively. Choroidal volumes increased by 6.4% (P<0.001) and 3.9% (P<0.001), respectively. There was no association between change in IOP and peripapillary (P = 0.27) or macular (P = 0.09) choroidal thickness. CONCLUSIONS Using automated segmentation of SS OCT measurements, significant increases in choroidal thickness and volume are observed after the WDT in healthy subjects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of Choroidal Thickness and Volume Measurements with Axial Length and Age Using Swept Source Optical Coherence Tomography and Optical Low-Coherence Reflectometry

PURPOSE To report choroidal thickness and volume in healthy eyes using swept source optical coherence tomography (SS-OCT). METHODS A prospective observational study of 122 patients examined with swept source OCT (DRI-OCT, Topcon, Japan). In each eye, we performed 256 horizontal scans, 12 mm in length and centered on the fovea. We calculated choroidal thickness manually with a built-in caliper...

متن کامل

Comparison of Choroidal Thickness in Psoriasis and Control Groups Using Optical Coherence Tomography

Background and Objective: One of the most common extracutaneous complications in psoriasis patients is ocular complications, which is controversial concerning its effect on choroidal thickness. This study aimed to compare the psoriasis patients with healthy individuals in terms of the thickness of the choroidal layer using the optical coherence tomography technique. Materials and Methods: In t...

متن کامل

Macular choroidal thickness and volume in normal subjects measured by swept-source optical coherence tomography.

PURPOSE To study the choroidal thickness in healthy subjects by swept-source optical coherence tomography (SS-OCT) at longer wavelength. METHODS The macular area of 31 eyes (31 healthy volunteers) was studied with an SS-OCT prototype system, which uses a tunable laser as a light source operated at 100,000 Hz A scan repetition rate in the 1-μm wavelength region. Three-dimensional volumetric me...

متن کامل

Macular Choroidal Thickness and Volume Measured by Swept-source Optical Coherence Tomography in Healthy Korean Children

PURPOSE To evaluate the thickness and volume of the choroid in healthy Korean children using swept-source optical coherence tomography. METHODS We examined 80 eyes of 40 healthy children and teenagers (<18 years) using swept-source optical coherence tomography with a tunable long-wavelength laser source. A volumetric macular scan protocol using the Early Treatment Diabetic Retinopathy Study g...

متن کامل

Automatic Measurement of Choroidal Thickness with Swept-Source Optical Coherence Tomography for Clinical Follow-Up in Acute Vogt-Koyanagi-Harada Disease

Background: The course of acute Vogt-Koyanagi-Harada is typically assessed qualitatively using indocyanine green angiography. Swept-source optical coherence tomography may provide a safer, non-invasive, more objective approach to follow up. In this study, we assess the clinical value of the automated measurement capabilities of swept-source tomography to measure choroidal thickness. Design: Pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 120 12  شماره 

صفحات  -

تاریخ انتشار 2013