Simultaneous kinetic spectrophotometric determination of citric and ascorbic acid by H-point standard addition method
نویسندگان
چکیده
The H-point standard addition method was applied to kinetic data for simultaneous determination of citric and ascorbic acid or selective determination of ascorbic acid in presence of citric acid. The method is based on the difference in the rate of reaction of citric and ascorbic acid with copper(II)-ammonia complex. The linear dynamic ranges for the two analytes of citric and ascorbic acid are 0.80-1.15 × 10 and 0.70-10.00 mM, respectively. The proposed method was successfully applied for the determination of citric and ascorbic acid in some powdered drink mixtures and vitamin C tablet.
منابع مشابه
Simultaneous Spectrophotometric Determination of Vanadium(V) and Iron(III) in Micellar Medium by H-Point Standard Addition Method
H-Point Standard Addition Method (HPSAM) was applied for the simultaneous determination of V(V) and Fe(III). The method is based on the complex formation of V(V) and Fe(III) with chromazurol S (CAS) in acidic media and in the presence of cetyltrimethylammonium bromide (CTAB) as a micellizing agent. Acidic media and the presence of a micellar system improve selectivity and sensitivity. Fe (I...
متن کاملA Highly Sensitive Kinetic Spectrophotometric Method for the Determination of Ascorbic Acid in Pharmaceutical Samples
In this study, a new reaction system for quantitative determination of ascorbic acid was introduced. The developed method is based on inhibitory effect of ascorbic acid on the Orange G-bromate system. The change in absorbance was followed spectrophotometrically at 478 nm. The dependence of sensitivity on the reaction variables including reagents concentration, temperature and time was investiga...
متن کاملKINETIC DETERMINATION OF ASCORBIC ACID a WITH SPECTROPHOTOMETRIC DETECTION
A simple and rapid method has been developed for the determination of ascorbic acid in fruit and pharmaceutical products. The method is based on the measurement of the reaction rate between ammonium molybdate and ascorbic acid in acidic media. The reaction was monitored spectrophotometrically at 800 nm by fixed-time and variable-time methods. The calibration graph was linear in the range of...
متن کاملA Highly Sensitive Kinetic Spectrophotometric Method for the Determination of Ascorbic Acid in Pharmaceutical Samples
In this study, a new reaction system for quantitative determination of ascorbic acid was introduced. The developed method is based on inhibitory effect of ascorbic acid on the Orange G-bromate system. The change in absorbance was followed spectrophotometrically at 478 nm. The dependence of sensitivity on the reaction variables including reagents concentration, temperature and time was investiga...
متن کاملSpectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run
A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...
متن کامل