Clinical comparison of Sentinel, a novel blood culture system, with radiometric Bactec 460 and Isolator 10 in the detection of streptococcal and anaerobic bacteraemias.

نویسندگان

  • N A Hutchinson
  • D C Shanson
  • T Malins
چکیده

AIMS To compare the performance of the Sentinel blood culture system with two other systems for the recovery of streptococci and anaerobes. METHODS Blood cultures were taken from 55 patients one to two minutes after dental extraction. The samples were tested by the radiometric Bactec 460; the Isolator 10, which works by lysis centrifugation; and Sentinel, a fully automated system, which detects bacterial growth by changes in the voltage between two electrodes in the media. Positive samples were subcultured and streptococci and anaerobes were further identified. Terminal subcultures were performed on all negative samples. RESULTS Sentinel was comparable with Bactec, with Sentinel recovering 20 streptococci and 14 anaerobes; Bactec isolated 26 streptococci and 15 anaerobes. The recovery of Streptococcus sanguis was significantly better from Bactec than Sentinel. The Isolator 10 recovered significantly fewer streptococci and anaerobes than either Bactec or Sentinel. Sentinel was noticeably quicker in detecting anaerobes than Bactec 460. However, there was no comparable difference with streptococci. Contaminants were recovered from 10% of Isolator 10, 2.7% of Bactec, and 7.2% of Sentinel bottles. CONCLUSIONS Sentinel and Bactec 460 were broadly comparable in the detection of viridans streptococci and oral anaerobes, and both systems were significantly better than the Isolator 10. However, the prototype Sentinel, was significantly poorer than Bactec for the recovery of S sanguis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical comparison of lysis-centrifugation and radiometric resin systems for blood culture.

The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours & Co., Inc., Wilmington, Del.) and the BACTEC 16B-17D radiometric resin system (Johnston Laboratories, Inc., Towson, Md.) both remove antimicrobial agents from the blood for culture. We compared these two systems for recovery of aerobic bacteria, facultatively anaerobic bacteria, and yeasts. A total of 5,000 blo...

متن کامل

Clinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media.

The efficiency of the 10-ml Isolator (E. I. du Pont de Nemours & Co., Inc.) for recovery of pathogens from blood was compared with that of BACTEC 6B and 7C media (Johnston Laboratories) by using 4,195 cultures from 1,662 patients. During the first phase of the study, BACTEC bottles were inoculated with 3 ml of blood; in the second phase, bottles were inoculated with 5 ml. The objectives were to...

متن کامل

Clinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children.

The Isolator 1.5 microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington , Del.) was compared with the BACTEC radiometric detection system (Johnston Laboratories, Inc., Cockeysville, Md.) for the detection of bacteremia in children. The Isolator 1.5 is a blood culture system designed for small volumes of blood (0.5 to 1.5 ml). The method involves lysis of the cells of the patient and t...

متن کامل

Clinical comparison of isolator and BACTEC 660 resin media for blood culture.

The 10-ml Isolator system (E.I. du Pont de Nemours & Co., Inc., Wilmington, Del.) was compared with the BACTEC 16A-17A nonradiometric resin system (Johnston Laboratories, Inc., Towson, Md.) for isolation of organisms from 6,839 paired blood cultures. Equal volumes of blood (6 to 10 ml for each Isolator and 3 to 5 ml for each BACTEC bottle) were cultured in parallel in the two systems, and 600 i...

متن کامل

Assessment of the BACTEC NR660 blood culture system for the detection of bacteremia in young children.

The sensitivity of the BACTEC NR660 blood culture system was assessed by using paired bottles of anaerobic (NR7A) and resin-containing aerobic (NR16A) media and conditions and organisms which simulated those found in pediatric practice. Corresponding media (7D and 16B) of the established BACTEC 460 radiometric method served as controls. The performances of the two systems were similar with 50 i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 45 6  شماره 

صفحات  -

تاریخ انتشار 1992