Effectiveness of "direct" stenting without balloon predilatation (from the Multilink Tetra Randomised European Direct Stent Study [TRENDS]).
نویسندگان
چکیده
The purpose of the TRENDS trial was to assess the safety, efficacy, and cost effectiveness of a no-predilatation ("direct") stenting strategy in the treatment of de novo native coronary artery lesions using the Multilink Tetra stent system. In this multicenter, prospective clinical trial, 1,000 patients were randomized (1:1) to receive a Multilink Tetra stent with or without balloon predilatation. The primary outcome measurement was major adverse cardiac events (MACEs) at 30 days; secondary end points included resource utilization (including procedural duration, equipment use, and length of hospital stay), MACEs, and angiographic binary restenosis at 180 days. In the predilatation group, 587 stents were implanted in 499 patients; in the direct group, 579 stents were implanted in 501 patients. In the direct group, stents in 31 lesions (5.7%) required predilatation and multivariate analysis identified calcification (odds ratio 5.81), angulation (odds ratio 5.34), and preprocedural minimal lumen diameter (odds ratio 0.09) as direct stenting failure. MACEs at 30 days were similar in the 2 groups, with 19 (3.8%) in the predilatation group and 13 (2.6%) in the direct group (p = NS). Resource utilization favored the direct strategy, with decreases in balloon use, contrast media, and procedure time, but a larger number of guiding catheters was used. The 180-day MACE rate of 9.8% in the direct group was not significantly less than the rate of 10.8% in the predilatation group (p = NS). Quantitative angiographic follow-up at 6 months demonstrated in-stent binary restenotic rates of 11.4% in the predilatation group (late loss 0.88 +/- 0.53 mm) and 12.3% in the direct group (late loss 0.82 +/- 0.51 mm, p = NS) and in-segment restenosis rates of 12.2% and 13.4%, respectively (p = NS). In conclusion, a direct stenting strategy with the Multilink Tetra stent was feasible and safe in 94% of lesions and associated with lower resource utilization compared with a predilatation approach. Direct stenting was not associated with significantly lower MACE and target lesion revascularization rates and had no effect on late angiographic follow-up, with similar late loss reflecting an identical biologic response to bare metal stent placement.
منابع مشابه
[Comparison of intracoronary ultrasound expansion parameters in coronary stents implanted with or without balloon predilatation. A randomized intravascular ultrasound study].
INTRODUCTION AND OBJECTIVES Coronary stenting without balloon predilatation is a safe technique associated with similar clinical results and lower costs, use of contrast and exposure to radiation in comparison to stenting with predilatation. After direct stenting, expansion may be reduced if the stenotic lesion was not predilatated. This study compared a). stent expansion with and without ballo...
متن کاملRandomised comparison of coronary stenting with and without balloon predilatation in selected patients.
BACKGROUND The SWIBAP (stent without balloon predilatation) prospective randomised trial was designed to compare direct coronary stenting with stenting preceded by lesion predilatation with an angioplasty balloon. OBJECTIVE To determine the feasibility and safety of direct stenting in non-complex coronary lesions in a prospective study. PATIENTS AND DESIGN All patients < 76 years of age sch...
متن کاملDirect coronary stent implantation does not reduce the incidence of in-stent restenosis or major adverse cardiac events: six month results of a randomized trial.
STUDY OBJECTIVE To compare the long-term angiographic, clinical and economic outcome of direct stenting vs stenting after balloon predilatation. PATIENT POPULATION AND METHODS Four hundred patients with coronary stenoses in a single native vessel were randomized to direct stenting vs stenting after predilatation. A major adverse cardiac and cerebral event (MACCE) was defined as death, myocard...
متن کاملDirect coronary stenting in reducing radiation and radiocontrast consumption
INTRODUCTION Coronary stenting is the primary means of coronary revascularization. There are two basic techniques of stent implantation: stenting with balloon predilatation of stenosis and stenting without predilatation (direct stenting). Limiting the time that a fluoroscope is activated and by appropriately managing the intensity of the applied radiation, the operator limits radiation in the e...
متن کاملSafety of balloon pre-dilatation in the treatment of severe carotid artery stenosis.
AIM To assess early outcome of predilatation prior stenting of severe carotid artery stenosis and to evaluate early major adverse cardiovascular and cerebral events (MACCE). PATIENTS AND METHODS The study group consisted of 265 consecutive patients (200 males, 65 female, mean age 66.7 ± 8.6 years) in whom 275 percutaneous transluminal angioplasty (PTA) procedures of carotid arteries were perf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of cardiology
دوره 97 3 شماره
صفحات -
تاریخ انتشار 2006