Plasma C-Reactive Protein Is Not Related to Sinus Non-Conversion by Maze Procedure Adjunct to Mitral Valve Surgery
نویسندگان
چکیده
In Framingham cohort study, C-reactive protein was not associated with incident atrial fibrillation (AF) after adjustment for left atrial size. This study examined whether levels of plasma inflammatory markers would be significant risk factors for failed maze procedure for AF. This study enrolled 88 patients with mitral valve disease undergoing valve surgery (n=32, sinus control group) or concomitant maze procedure for persistent atrial fibrillation (AF) (n=56, AF group). The mean follow-up in the AF group was 55.0 ± 17.5 months. The AF and sinus control groups did not differ in preoperative levels of C-reactive protein (p=0.636). In the AF group receiving maze procedure, the sinus conversion (n=37) and non-conversion (n=19) groups did not significantly differ in preoperative levels of interleukin-6 (p=0.607) and tumor necrosis factor-α (p=0.379). In multivariate analysis after adjustment for preoperative plasma inflammatory markers, independent factors associated with sinus conversion were AF duration (p=0.003), and left atrial area (p=0.014). In conclusion, plasma inflammatory markers are not associated with sinus non-conversion by radiofrequency maze procedure.
منابع مشابه
Surgical treatment of atrial fibrillation with concomitant mitral valve disease: an Asian review.
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in patients with mitral valve disease and is present in up to 50% of patients undergoing mitral valve surgery, contributing to increased risks of systemic embolization, anticoagulant-related hemorrhage and mortality. The Cox maze III procedure, introduced in 1987 by Dr. James Cox, was the first effective operation for AF a...
متن کاملOutcome of Concomitant Cox Maze Procedure with Narrow Mazes and Left Atrial Volume Reduction
BACKGROUND TO IMPROVE SINUS RHYTHM CONVERSION, THE COX MAZE III PROCEDURE WITH NARROW MAZES (WIDTH: ≤3.0 cm) was performed in combination with left atrial volume reduction. METHODS From October 2007 to April 2013, 87 patients with atrial fibrillation (paroxysmal in 3, persistent in 14, and permanent in 70) underwent the Cox maze procedure concomitant with another cardiac procedure. They were ...
متن کاملOutcome of the modified maze procedure for atrial fibrillation combined with rheumatic mitral valve disease using cryoablation.
This study evaluated the mid-term results of the modified maze procedure using cryoablation for treating atrial fibrillation associated with rheumatic mitral valve disease. Between March 2000 and February 2004, 177 consecutive patients underwent the modified maze procedure using cryoablation concomitant with mitral valve surgery, were divided into the modified Cox-Maze III (group CM, n=88), mod...
متن کاملMini-maze suffices as adjunct to mitral valve surgery in patients with preoperative atrial fibrillation.
INTRODUCTION After mitral valve (MV) surgery, preoperative atrial fibrillation (AF) often recurs while cardioversion therapy generally fails. Additional Cox maze surgery improves postoperative arrhythmia outcome, but the extensive nature of such an approach limits general appliance. We investigated the clinical outcome of a simplified, less extensive Cox maze procedure ("mini-maze") as adjunct ...
متن کاملElectrocardiographic nature of restored sinus rhythm after Cox maze procedure in patients with chronic atrial fibrillation who also had other cardiac surgery.
OBJECTIVE To characterise heart rate variability and high frequency components of restored sinus rhythm after the maze procedure. The maze procedure for chronic atrial fibrillation may prevent thrombotic events and improve the quality of life. However, the electrocardiographic nature of restored sinus rhythm after the maze procedure has not been fully elucidated. PATIENTS AND METHODS Between ...
متن کامل