Modifications influencing Widal test reactivity in a novel microplate assay.

نویسندگان

  • Adel Almogren
  • Zahid Shakoor
  • Mustafa Hussein Adam
  • Mohammad Osman Gadelrab
  • Hassan Abdulaziz Musa
چکیده

Reliability of the Widal tube agglutination test has been the subject of many controversies over the years. This study was performed to assess the effect of certain modifications on the performance of Widal test in a novel microplate assay. Sera from 37 patients (21 males; 16 females) (mean age 28 +/- 7 years) were tested in the Immunology Unit at King Khalid University Hospital, Riyadh. Among them were 26 patients with suspected typhoid fever and 11 had bacteriologically confirmed diagnosis of Salmonella infection. The modifications included either the use of 0.5% bovine serum albumin (BSA), absorption of sera with sheep red blood cells (SRBC) or heat inactivation of sera. Compared with Widal tube agglutination test, microplate assay with SRBC absorption of the sera from patients with suspected typhoid fever was not only associated with enhancement of detection titers for both H (p < or = 0.001) and O (p < or = 0.005) Salmonella agglutinins but also the percentage of reactivity. The presence of BSA augmented detection titers for Salmonella H agglutinins (p < or = 0.02) only. Heat inactivation of sera however was found to be associated with reduction in the detectable titers for both H (p < or = 0.03) and O (p < or = 0.01) agglutinins. Increased titers of Salmonella agglutinins were also evident in 11 patients with confirmed diagnosis of Salmonella infection. The novel microplate agglutination assay using the SRBC absorption was associated with enhancement in Widal test reactivity and appears to be a useful alternative for the diagnosis of Salmonella infection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modifications In!uencing Widal Test Reactivity in a Novel Microplate Assay

Reliability of the Widal tube agglutination test has been the subject of many controversies over the years. !is study was performed to assess the e$ect of certain modifications on the performance of Widal test in a novel microplate assay. Sera from 37 patients (21 males; 16 females) (mean age 28 + 7 years) were tested in the Immunology Unit at King Khalid University Hospital, Riyadh. Among them...

متن کامل

Detection of Salmonella typhi agglutinins in sera of patients with other febrile illnesses and healthy individuals.

BACKGROUND AND PURPOSE Widal test is frequently applied for the detection of Salmonella agglutinins to diagnose Salmonella enterica serotype Typhi infection. There are however a number of controversies challenging the diagnostic utility of this test. This study was performed to determine the prevalence of Salmonella agglutinins in patients with other febrile illnesses and healthy blood donors. ...

متن کامل

Dihydrofolate reductase enzyme inhibition assay for plasma methotrexate determination using a 96-well microplate reader.

Microplate reader assays offer several advantages over conventional spectrophotometric assays. We adapted the dihydrofolate reductase (DHFR) enzyme inhibition assay for use in a 96-well microplate reader to measure plasma methotrexate (MTX) concentrations. The assay is linear from 0.01 to 0.1 micromol/L. The within-run CVs at 0.03 micromol/L and 0.08 micromol/L MTX were 4.0% and 2.7%, respectiv...

متن کامل

Comparative Evaluation of Standard Tube Test with Enzyme Linked Immunosorbant Assay and Indirect Fluorescent Assay Using Brucella Abortus S 99 Sonicated and Heat Extracted Antigen

Background: Brucella sps are Gram negative, facultative intracellular bacteria causing brucellosis in humans and animals. Since it is a multi-organ disease and symptoms are nonspecific the diagnosis by clinical finding is difficult and can be missed .Many serological tests have been used form the diagnosis of human brucellosis. This study compared the diagnostic value of in-house ELISA and IFA ...

متن کامل

Microplate-based chromatin immunoprecipitation method, Matrix ChIP: a platform to study signaling of complex genomic events

The chromatin immunoprecipitation (ChIP) assay is a major tool in the study of genomic processes in vivo. This and other methods are revealing that control of gene expression, cell division and DNA repair involves multiple proteins and great number of their modifications. ChIP assay is traditionally done in test tubes limiting the ability to study signaling of the complex genomic events. To inc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Polish journal of microbiology

دوره 61 2  شماره 

صفحات  -

تاریخ انتشار 2012