Occlusal status of implant superstructures at mandibular first molar immediately after setting
نویسندگان
چکیده
BACKGROUND Occlusal contact on the implant superstructures is important for successful treatment. The purpose of this study was to investigate the occlusal contact of single implant superstructures at the mandibular first molar immediately after seating from weak to strong clenching. METHODS Subjects were nine patients who had just been fitted with an implant prosthesis in the mandibular first molar region, with no missing teeth other than in the implant region. First, while masseter muscle activity was monitored, maximum clenching strength (100 % maximum voluntary contraction (MVC)) was determined with an electromyogram. Next, occlusal load and occlusal contact area were measured three times at clenching intensities of 40, 60, 80, and 100 % MVC by the use of pressure-sensitive film for occlusal force diagnostic and Occluzer for occlusal force measurement. Finally, the occlusal contact area was measured once each at 20, 40, and 60 % MVC using a silicone testing material and BiteEye for occlusal contact measurement. A two-way analysis of variance (ANOVA) was used to determine occlusal loading and occlusal area as dependent variables, and clenching strength and presence or absence of implant as between-subject factors. A multiple comparison test was performed using the Bonferroni method. RESULTS The occlusal contact area and occlusal load of the implant prosthesis increased with clenching strength, and the increases in occlusal contact area and occlusal load of the implant prosthesis were less than those of the contralateral tooth at high clenching strength. However, significant difference was not observed when compared with both sides of the molar region regardless of clenching strength. CONCLUSIONS The occlusal contact area of the implant had a tendency to be adjusted smaller than the natural tooth by a dental technician and a dentist. On the other hand, despite the small tissue displaceability of the implant, occlusal load on the implant prosthesis was smaller than on the natural tooth at high clenching strength.
منابع مشابه
Dental implant treatment after improvement of oral environment by orthodontic therapy.
A 57-year-old man presented with mesial inclination of the lower right first molar caused by untreated loss of the second premolar. The occlusal relationship was restored by dental implant treatment following improvement of the intraoral environment by orthodontic therapy. At his initial visit, the interdental spacing in the molar-premolar region was inadequate, as the first molar had mesially ...
متن کاملLocation of the Mandibular Canal and Thickness of the Occlusal Cortical Bone at Dental Implant Sites in the Lower Second Premolar and First Molar
The objective of this study was to evaluate the location of the mandibular canal and the thickness of the occlusal cortical bone at dental implant sites in the lower second premolar and lower first molar by using dental cone-beam computed tomography (CBCT). Seventy-nine sites (47 second premolar and 32 first molar sites) were identified in the dental CBCT examinations of 47 patients. In this st...
متن کاملAbutment fracture and the technique Used to Remove the fracture portion of the Abutmet: Case Report
Abstract This clinical report presents a case of abutment fracture, due to occlusal overload, occurred with an implant-supported restoration on right mandibular first molar of a female patient. After 6 months of prosthetic reconstruction implants, the patient returned to the clinic due to the loss of implant crown. The fractured fragment of the abutment with the screw protec...
متن کاملSignificance of mandibular molar replacement with a dental implant: a theoretical study with nonlinear finite element analysis
BACKGROUND Dental implants are frequently applied to unilateral defects in the mandible. However, implant placement in the molar region of the mandible can be difficult due to anatomical structure. The aim of this study was to evaluate the distribution of occlusal force in a mandibular shortened dental arch (SDA) with implants. METHODS Three-dimensional finite element (FE) models of the mandi...
متن کاملتعیین توزیع تنش استخوان اطراف ایمپلنتهای فک پایین در طرحهای مختلف پروتز به هنگام Mandibular- Flexure
Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...
متن کامل