The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube
نویسندگان
چکیده
INTRODUCTION Although serum-providing blood tubes with a barrier are still widely used due to their significant advantages, the use of blood tubes with a barrier to provide plasma is becoming widespread. We compared 22 analytes in a BD Vacutainer® Barricor LH Plasma tube for local clinical validation of this new lithium heparin tube with a barrier. MATERIALS AND METHODS Samples from 44 volunteers were collected in different tubes (Becton Dickinson and Company): Z tube without additive (reference), clot-activator tube with gel (SST), lithium heparin tube without gel (LiH), and lithium heparin tube with barrier (Barricor). Analyte concentrations in different tubes were compared with the reference tube. All tubes were also evaluated according to additional testing (different centrifugation durations, blood-sampling techniques and individual differences). RESULTS Aspartate aminotransferase (AST), glucose (Glc), potassium (K), lactate dehydrogenase (LD), sodium (Na), and total protein (TP) had a significant bias in Barricor (9.19%, - 3.24%, - 4.88%, 21.60%, - 0.40%, 5.03%, respectively) relative to the reference tube. There was no statistical difference between different centrifugation durations and individual differences for AST, K and LD in LiH and/or Barricor (P > 0.05). There was a significant bias for LD between LiH and Barricor in terms of blood-sampling techniques (21.2% and 12.4%, respectively). CONCLUSIONS Recently, the use of plasma has become prominent due to some of its advantages. In this study, plasma AST, K, LD, Glc and TP levels in Barricor were clinically different in comparison to serum. The results of additional tests showed that higher levels of LD in Barricor did not result from haemolysis, and they might be related to other factors including number of platelets, cellular fragility, or functional environment.
منابع مشابه
Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays.
We investigated the use of serum samples from BD Vacutainer rapid serum tubes (RSTs; BD, Franklin Lakes, NJ) to reduce undetermined interferences contributing to false-positive immunoassay results in heparin plasma samples. Patients being evaluated for suspected myocardial infarction had specimens drawn into an RST in addition to the standard lithium-heparin plasma separator tube (PST). We meas...
متن کاملInfluence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes
Introduction Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. Materials and methods We coll...
متن کاملComparison of paraoxonase 1 measurements in serum and in lithium-heparin-anticoagulated plasma samples.
To the Editor: Paraoxonase 1 (PON1) is a HDL-associated enzyme that catalyzes the hydrolysis of lipid peroxides in LDL and HDL and has been postulated as a member of the plasma antioxidant system. Decreased PON1 activity has been associated with atherosclerosis in persons with diabetes mellitus, familial hypercholesterolemia, and renal disease (1, 2). Serum is the preferred sample for PON1 meas...
متن کاملQuantification of Plasma or Serum Short-Chain Fatty Acids: Choosing the Correct Blood Tube
Background: Short-Chain Fatty Acids (SCFA; acetate, propionate and butyrate) are more and more recognised as mediators of local gut and systemic health. Quantification of SCFA in plasma and serum is challenging due to their low concentrations in human blood and the ubiquitous nature of acetate, requiring careful standardisation of the sample preparation procedure. Also the choice of the blood t...
متن کاملStability of plasma electrolytes in Barricor and PST II tubes under different storage conditions
INTRODUCTION Sample stability can be influenced by many different factors; evaporation and leakage from residual cells are the most relevant factors for electrolytes. During the analytical phase, samples are usually kept uncapped at room temperature. Once samples are processed, they are usually stored sealed and refrigerated. Long turnaround time and the possibility of "add-on test" need consid...
متن کامل