In vitro wear simulation on the RandomPOD wear testing system as a screening method for bearing materials intended for total knee arthroplasty.
نویسنده
چکیده
The 16-station RandomPOD wear test system, previously validated for prosthetic hip wear, was used in the simulation of knee wear mechanisms with a ball-on-flat test configuration. This consisted of a CoCr pin with a ground and polished spherical bearing surface (radius 28 mm) against a conventional, gamma-sterilized UHMWPE disk in serum lubrication. The biaxial motion, consisting of x and y translations, and the load was non-cyclic. Relative to the disk, the center of contact wandered within a circle of 10mm diameter, and the average sliding velocity was 15.5mm/s (ranging from 0 to 31 mm/s). The load varied non-cyclically between 0 and 142 N (average 73 N). In the 60-day test with 16 similar wear couples, moderate adhesive wear, the principal wear mechanism of a well-functioning prosthetic knee, dominated. This showed as a burnished, circular wear mark (diameter 13.2mm, area 137 mm(2)). The wear factor was 2.04 ± 0.03 × 10(-6)mm(3)/Nm (mean ± 95 percent confidence limit). For the first time a truly multidirectional, realistic and uniform, large capacity pin-on-disk simulation of knee wear mechanisms was implemented.
منابع مشابه
Biotribology in Knee Arthroplasty
During the last decade, new bearing materials, new methods in in vitro wear simulation, specific cell culture, and animal models to evaluate the response to particulate debris, and dedicated retrieval analysis programs to learn more about material degradation in vivo have been developed in the field of biotribology. Improvements in knee arthroplasty design, materials, sterilisation techniques, ...
متن کاملA hybrid apparatus for friction and accelerated wear testing of total knee replacement bearing materials
The statistical survivorship of total knee replacement (TKR) devices declines dramatically after fifteen years of use because the articulating surfaces wear, and biologically active wear particles may induce osteolysis and subsequent loosening of the implant. This lack of durability leads to revision surgery or surgery postponement. Thus, friction and wear evaluation is of primary concern when ...
متن کاملPEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: An experimental wear study
New bearing materials for total joint replacement have been explored as the need to improve longevity and enhance performance is driven by the changing demands of the patient demographic. Carbon-reinforced PEEK has demonstrated good wear characteristics in experimental wear simulation in both simple geometry pin-on-plate studies and in total hip joint replacement. Carbon reinforced PEEK CFR-PEE...
متن کاملWear of ceramic-on-carbon fibre reinforced PEEK hip replacements
Total hip replacement has been a successful surgical intervention for many years. However, concerns regarding UHMWPE wear particle induced osteolysis [1], have led to alternative bearing materials to be sought. Carbon-fibre reinforced poly-ether-ether-ketone (CFR-PEEK) is a fibre-reinforced polymer which has shown reduced wear in hip and knee configurations compared with conventional polyethyle...
متن کاملComparative gravimetric wear analysis in mobile versus fixed-bearing posterior stabilized total knee prostheses.
Polyethylene (PE) wear is the limiting factor for the longevity of a conventional total knee arthroplasty (TKA). Excessive wear leads to loosening and eventual implant failure. The aim of our in vitro study was to investigate wear of a PE tibial insert on a rotating platform as compared to the same insert fixed to the tibial baseplate and articulating with a similar femoral component. All tests...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 47 11 شماره
صفحات -
تاریخ انتشار 2014